American Power Conversion 10-40kW manual Programming Keys, Switching to Bypass Operation

Page 22

Parameter Settings

4.1Programming Keys

Displays time

Return to normal window

Accesses the alarm stack

Scrolls up through list

Scrolls down through list

Stores parameters/enters parameter stack

Silences the audible alarm

Chooses or changes parameters

4.2Switching to Bypass Operation

Programming Example

Action

 

 

Display shows

1.

Press

to enter parameter stack

 

2.

Press

or

until

Bypass operation

: NO

3.

Press

until

 

Bypass operation

 

: YES

 

 

 

 

4.

Press

to store

 

 

5.

Press

to exit

 

Bypass operation

 

 

 

 

 

990-4043

22

User Guide APC Silcon 10-40kW 400V UPS

Image 22
Contents 10-40kW 400V UPS User Guide Copyright 2000 APC Denmark ApSUser Guide APC Silcon 10-40kW 400V UPS Safety Symbols used in this manualThank You Contents Introduction IntroductionDisplay Unit Stop UPS for stand-by Stop/Start UPS and Operating the External Service BypassNormal operation Load power xx% Start UPS from stand-bySwitching off the UPS Stop UPS for complete power downBlank Start UPS from complete power down UPS start-upDisplay shows Bypassing the Single System UPS Operating the External Service Bypass Switch single systemsBypass operation Stop/Start UPS and Operating the External Service Bypass System OFF Normal operation Load power 0% Bypass operation Bypass operation Normal operation Load power 0%Bypassing the Parallel UPS System All UPSs Press On the keyboard until Stop/Start UPS and Operating the External Service Bypass Press the green on button on all systems Set input switches Q001 to positionPress On the keyboard Isolating one UPS in a Parallel/Redundant System Stop/Start UPS and Operating the External Service Bypass Operation OperationKeyboard Display of Measured Values Using the Remote DisplayBatt. load Batt. tank Economy Mode Parameter Settings Parameter SettingsParameter Settings Programming Keys Switching to Bypass OperationProgramming Example Load power xx% Displaying the Alarm Stack Alarms and EventsAlarms and Events Mode CommentsPossible Alarms Alarms Description ActionDisplay will show invalid UPS data Parallel Operation Alarms Rectifying Alarm MessagesCorrection of false alarm situations during service Battery Monitoring Test Maintenance & TestingMaintenance & Testing Battery Capacity TestTest Xxx Press Battery capacity TestUntil Test PressWarranty WarrantyAPC Silcon UPS Limited Factory Warranty APC Corporate How to Contact APCHow to Contact APC APC Denmark