GBC 3064WF operation manual Tension, Service Agreement

Page 27

GBC 3064WF

 

Operation Manual

 

 

 

TROUBLE SHOOTING GUIDE

 

 

 

 

 

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

 

 

 

The control panel display does not

Laminator not connected to electrical

Insert attachment plug into

illuminate when POWER ON/OFF

supply

receptacle

is in the ON, marked “I”, position.

Blown out fuse.

Check fuses.

Heat rollers do not turn when

Feed table not properly installed.

Tilt feed table and properly replace

POWER ON/OFF is in the ON,

 

it.

marked “I”, position.

 

 

Press the “RUN” ( ) button and the

E-Stop button activated

Pull out on the E-STOP turn

motor does not turn.

 

clockwise.

Heat rollers only turn if I use the

Photo eye is blocked.

Disengage the footswitch mode.

“Footswitch”.

 

Clear nip area.

Laminated items exhibit curling.

Tension between the top and bottom

Adjust tension per section FILM

 

film. Roll is unequal.

TENSION.

 

Tension on top or bottom roll of film

Adjust tension per section FILM

 

is too film is too loose.

TENSION.

 

Bottom film roll may be improperly

Make sure bottom roll of film is

 

loaded.

around idler bar and that is the

 

 

normal operation position.

Adhesive deposited on heat rollers.

Top and bottom film webs not

Release heat and pull roller pressure,

 

aligned

align the rolls of film.

 

Laminate improperly loaded.

Adhesive (matte) side of laminate

 

 

film may be against the heat rollers.

 

 

Unweb and reload the film properly.

 

Speed setting too fast for type of

Lower speed setting.

 

material being laminated

 

 

Insufficient heat

Wait for “READY” indicator to

 

 

appear in the control panel display.

 

Laminate improperly loaded

Adhesive side of film must be facing

 

 

away from the heat rollers.

 

Heat rollers require cleaning.

Bottom roll of film not threaded

 

 

behind the idle bar.

 

Laminated item unsuitable for

Clean heat rollers per procedure in

 

adhesion.

section CARING FOR THE GBC

 

 

3064 WF LAMINATOR. Item may

 

 

be dirty or may have non porous

 

 

surface that is extremely difficult to

 

 

laminate.

 

 

 

SERVICE AGREEMENT

 

 

GBC’s Equipment Maintenance Agreement will insure the quality performance and long life built into your laminator.

A service charge for travel time, labor and parts may be incurred for each out of warranty service call. GBC’s Equipment Maintenance Agreement decreases these expenses and protects your valuable investment. GBC offers several types of agreements to suit your needs and budget. To contact

GBC write to:

 

 

GBC NATIONAL SERVICE

IN CANADA:

GBC NATIONAL SERVICE

ONE GBC PLAZA

 

49 RAILSIDE ROAD

NORTHBROOK, IL 60062 U.S.A.

 

DON MILLS, ONTARIO

 

 

M3A 1B3

General Binding Corporation

 

 

One GBC Plaza

 

 

Northbrook, IL 60062-4195

 

 

®

 

 

© 2005 General Binding Corporation

Page 27

Image 27
Contents ENG ENG GBC 3064WFTable of Contents General Important Safety InstructionsImportant Safeguards ServiceSpecifications WarrantyPRE-INSTALLATION InstallationGBC 3064 WF Requires Control Guide Power ON/OFF I/OFeatures Guide Unwind / Rewind Combo Media Tables C & 3CRemovable Chill Idler Item a Lower Tension Idler Item B Upper Tension Idler Item aSwing around control panel arm Item a Main On Off I/O SwitchElectronic Safety Beam Item a Heated Main Rollers Item aHeated Main roll Lift handle Nip Pressure AdjustmentPull Roll Clutch Adjustment Knob Pull Roll Lift handleSpeed of 3f/m Sequence of OperationsOperating Instructions Film Loading & ThreadingTo load a roll of film Fig Webbing Thermal Film Using Threading Card Webbing PSA Film/Mount Adhesive Using Threading Card Start Laminating Rollers Method for Tacking New Film to Existing FilmTo unweb the laminator Clearing a Film Jam Wrap-upTo clear a jam Tips for Single Sided lamination ApplicationsTips for Pre Coating Boards Tips for Mounting Pre Coated BoardsTips for Creating a Decal Tips for mounting a DecalTips For Thermal Encapsulation Tips for Accushield ART of Lamination Speed / Temperature ControlOutput HeatCaring For The GBC 3064WF Laminator MaintenanceTension Service Agreement