Stylus Photo R300/R310 | Revision A |
2.3.11 Removing APG Assy.
External View
Hook
Tab
CN7
Screwing Tab
APG Assy.
Acetate Tape
Parts/Units which should be removed before removing "APG Assy." Paper Support Assy./Housing, Upper/Housing, Middle
Procedure for Removing
1.Disconnect the connector cable of "PG Motor" from CN7 of "Main Board".
2.Release the connector cables of "PF Motor" and "PG Motor" from the following points.
Acetate tape
Hook of "ASF Assy."
Tab of "Paper Guide, CDR" (x2)
Screwing tab of "Housing, Lower"
3.Remove the screw which secures "APG Assy.". Then, remove "APG Assy.".
Make sure that the hooks (x2) and the dowels (x2) of "APG
Assy." are securely attached to "Frame, Main".
Check if the part indicated in the following figure is inserted in the slits of "Frame, Main".
C.B.S 3x6
Figure 2-26. Removing "APG Assy."
It has to be inserted in the slit of "Frame, Main"
Dowel
Hook
APG Assy.
Figure 2-27. Reinstalling "APG Assy."
DISASSEMBLY AND ASSEMBLY | Disassembly | 55 |