EPSON Stylus Photo R300/R310 | Revision A |
Table 1-11. Check Points for Fatal Error to Each Phenomenon
Occurrence Timing
Position of CR
Phenomenon Detail
Faulty Part/
Part Name
Check Point
Remedy
"CR Motor" does not work at all when |
| 1. | Check if "CR Motor Connector Cable" is connected to | 1. | Connect "CR Motor Connector Cable" to | ||
CR Motor |
| CN8 on "Main Board". |
| CN8 on "Main Board". | |||
turning on the power. |
|
| |||||
| 2. | Check if "CR Motor Connector Cable" is not damaged. | 2. | Replace "CR Motor" with a new one. | |||
|
| ||||||
|
|
|
|
|
|
|
|
|
| 1. | Check if "PF Motor Connector Cable" is connected to | 1. | Connect "PF Motor Connector Cable" to CN9 | ||
|
|
| CN9 on "Main Board". |
| on "Main Board". | ||
| PF Motor | 2. | Check if the resistance of "PF Motor" is approximately | 2. | Replace "PF Motor" with a new one. | ||
|
|
| 3.0Ω using a tester. Refer to Table |
|
| ||
|
| 3. | Check if "PF Motor Connector Cable" is not damaged. | 3. | Replace "PF Motor" with a new one. | ||
|
|
|
|
|
|
|
|
|
| 1. | Check if "Compression Spring, 2.36" of "Lever, Change" | 1. | Replace "Ink System" with a new one. | ||
"Carriage Unit" strikes on "Lever, |
|
| has not come off. |
|
| ||
|
|
|
|
|
|
| |
Change" which is leaning forward when |
|
|
|
|
|
|
|
|
|
| Lever, Change |
|
|
| |
turning on the power. |
|
|
|
|
|
| |
Ink System |
|
|
|
|
|
| |
|
|
|
|
|
|
|
At
Out of HP
Compression Spring, 2.36
1. Check if "Paper Guide, Upper" has not come off from | 1. Reassemble "Paper Guide, Upper" to "Main | ||
"Main Frame". | Frame". | ||
|
|
|
|
| Paper Guide, Upper |
|
"Carriage Unit" strikes on "Paper Guide, | Paper Guide, | |
Upper" which has come off from "Main | ||
Upper | ||
Frame" when turning on the power. | ||
|
At | "Carriage Unit" strikes on the right side |
| 1. Check if "CR Scale" has not come off or it properly | 1. Reassemble "CR Scale" correctly. | |
of "Main Frame" when turning on the | CR Scale | passes through the slit of "CR Encoder Sensor Board". | * If the problem is not solved, replace | ||
Anywhere | |||||
power. |
|
| "Main Board" with a new one. | ||
|
|
| |||
|
|
|
|
|
TROUBLESHOOTING | Unit Level Troubleshooting | 24 |