1-2 Servicing Precaution

WARNING 1: First read the Safety Precaution section of this manual. If some unforeseen circumstance creates a conflict between the servicing and safety precautions, always follow the safety precaution.

WARNING 2: An electrolytic capacitor installed with the wrong polarity might explode.

1.Always unplug the unit’s AC power cord from the AC power source or the Power Switch off before attempting to:

(a)Remove or reinstall any component or assembly,

(b)Disconnect an electrical plug or connector,

(c)Connect a test component in parallel with an electrolytic capacitor.

2.Some components are raised above the printed circuit board for safety.

An insulation tube or tape is

sometime used. The internal wiring is sometimes clamped to prevent contact with thermally hot components. Reinstall all such elements to their original position.

3.After servicing, always check that the screws, components and wiring have been correctly reinstalled.

Make sure that the portion around the serviced part has not been damaged.

4.Check the insulation between the blades of the AC plug and accessible conductive parts (example: metal panels and input terminals).

5.Insulation Checking Procedure: Disconnect the power cord from the AC source and

turn the power switch

ON. Connect an insulation resistance meter (500V) to the blades of the AC plug. The insulation resistance

between each blade of the AC plug and accessible conductive parts (see above) should be greater than 1 mega-ohm.

6.Never defeat any of the B+ voltage interlock. Do not apply AC power to the unit (or any of its assemblies)

unless all solid-state heat sinks are correctly installed.

7.Always connect an instrument’s ground lead to the instrument chassis ground before connecting the positive lead; always remove the instrument’s ground lead last.

Rev. 1.00

- 5 -

Image 5
Contents SRP-F310/312 SRP-F310/312 Remaining Roll Paper Adjustment Safety Precautions Precaution SegmentServicing Precaution Operational Precautions Precaution for Electrostatically Sensitive Devices ESDsAC Adapter Installation InstallationInterface Cable Installation USB Cable InstallationDongleUsb A-Type Cable Installation Ethernet Cable InstallationCover Open Installation Paper Roll InstallationSetting the DIP switch RS-232C Serial Interface Setting the DIP switchesSetting the DIP switch IEEE1284 Parallel, USB Interface ※ Auto Cutter Enable / Disable selectionHexadecimal Dumping Self Test Mode10 The Self-Test Sheet MSW2 Setting the Memory SwitchesMSW1 MSW4 MSW3BXL/POS MSW5 OFF SHIFT-JIS BIG5MSW6 MSW11Appearance Printer Dimensions mmAC Adapter Dimensions mm USB B-TYPE Feature Locations-SRP-F310/312Ethernet SmpsUSB General SpecificationsRAM Printer Specification Thermal Printer SpecificationsCharacter Specification SRP-F310 TPH KRB-72-7TA02-BIX2,KYOCERA CorporationReliability and Environment Specification Paper Specification※ Note McbfPrintable Area TPH Thermal Printer Head SpecificationALL-HIGH Other Component SpecificationSmps Switching Mode Power Supply Specification Smps SpecificationsSmps Output Connector GND1 RS-232C Serial Interface 1a Specification Interface SpecificationsXON/XOFF 1b RS-232C I/F Cable1c Cable Connection 1d Signal DescriptionPrinter Host Side 9P1e H/W Flow Control 2a Forward Mode Specification Compatibility mode1f S/W Flow Control IEEE1284 Parallel Interface2c IEEE1284 I/F Cable 2c Signal Specification Compatibility/Nibble/Byte mode3b Signal Description 3a Specification3 USB2.0 Interface 3c Cable4d Construction USB CableSeries a Connectors Series B Connectors 10 illustrates the keyed connector protocolCable Connection Cash Drawer SpecificationsDrawer Cable Ethernet Ethernet SpecificationsWPA/WPA2TKIP/AES-CCMP PSK WlanHardware Wiring DiagramBlock Diagram Rev SRP-F310/312 SRP-F310/312 SRP-F310/312 Block Diagram Special Circuit Descriptions Power CircuitIEEE1284 Logic IC Driving Voltage +5VDC CPU A/D, USB core and OSC Voltage +2.5VDCCPU core Voltage +1.2VDC Reset CircuitFpga core Voltage +1.5VDC Cash Drawer Driving Circuit Buzzer and Cash Drawer Circuits Buzzer Driving Circuit5 RS-232C Communication Block Diagram 4 I/F PBA Detect Block DiagramPBA MD0 MD1 MD2DIP Switch Circuit Parallel Communication Block DiagramUSB Communication Block Diagram STB1 Thermal Printer Head CircuitSTB2 CPUCase lower block Disassembly and AssemblySRP-F310/312 SRP-F310/312 ③SPRING Hinge Case Upper blockSRP-F310/312 SRP-F310/312 Frame block ②HOUSING P-END Remaining Roll Paper Adjustment AdjustmentMaintenance Troubleshooting flow chart TroubleshootingPower LED does not light Paper and Error led blink Paper and Error led lit Paper led lit Error led blink Error led lit Self test is not normal OK?YES Noend Data from host is not printed normallyPower Problem Printing Quality Problems Auto Cut Mechanism Problems Printer Mechanism Problems