26
OS/2 Windows NetWare
UNIX Macintosh
Management and Configuration | AXIS 560/660 User’s Guide |
|
|
Using the Test Button
The following operations can be performed by pressing the test button in different sequences. Please refer to Product Overview, on page 5, to identify the location of the test button.
Printing a test page:
•Press the test button once to print a test page.
Printing the parameter list:
•Press the test button twice to print the parameter list.
Resetting the AXIS 560/660 parameters to the factory default settings:
1.Remove the external power supply to switch off the AXIS 560/660.
2.Press and hold down the test button, while you reconnect the external power supply. Continue to hold down the test button until the network indicator starts to flash at one second intervals. This should take about 5 seconds.
3.Release the test button and wait until the network indicator flashes at least five times.
4.Press and hold down the test button again until the network indicator remains constantly lit.
5.Restart the AXIS 560/660 by disconnecting and reconnecting the external power supply.
Note:
All parameters except the node address (NODE_ADDR.), the IP address (IP_ADDR.) and DHCP enabled or disabled (DHCP_ENABLE.) are reset.
Please refer to the AXIS 560/660 User’s Manual for more information about the test button.