2.3Configuration Command String
The Configuration Command String sets the operating parameters of the Printer. The Command Strings are described below.
<STX>KDwxy <CR> where w:
Bit # | Function | Value |
Baud Rate | 0=9600, 1=600, 2=2400, 3=19200, 4=4800, 5=N/A, | |
|
| 6=1200, 7=9600 Test Mode |
3 | Word Length | 0=8 bits, 1=7bits |
4&5 | Unused | Set to 0 |
6 | Always 1 | Set to 1 |
7 | Always 0 | Set to 0 |
where x: |
| |
Bit # | Function | Value |
0 | Print Method | 0=direct, 1=transfer |
1 | Present Sensor | 0=not equipped, 1=equipped |
2 | Alternate Char. | 0=standard, 1=main frame |
| Set |
|
3 | Cutter | 0=disabled, 1=enabled |
4&5 | Unused | Set to 0 |
6 | Always 1 | Set to 1 |
7 | Always 0 | Set to 0 |
where y: |
| |
Bit # | Function | Value |
0&1 | Paper Type | 0=gap(edge), 1=reflective, 2=continuous (3") |
2 | Linerless | 0=not equipped, 1=equipped |
Unused | Set to 0 | |
6 | Always 1 | Set to 1 |
7 | Always 0 | Set to 0 |
Example:
<STX>KD @A@ <CR>
@Sets the Printer to: 9600 baud; 8 bit word length/no parity.
ASets the Printer to: thermal transfer; no present sensor; standard character set; no cutter.
24 | Printing Labels |