3. PERIODIC MAINTENANCE PROCEDURE |
3. PERIODIC MAINTENANCE PROCEDURE
5.Apply FLOIL
6.Clean the Cutter Blade with a cotton swab moistened with absolute ethyl alcohol.
Cutter Blade
Cutter Unit
7.Confirm that the problem occurs as reported, and then take corrective action.
8.Replace the following parts periodically, if necessary. The following table shows approximate product life for each part.
No. | Part Name | Part No. | Standard interval of | |
replacement | ||||
|
|
| ||
|
|
|
| |
1 | Cutter unit (Option) | 1,000,000 cuts | ||
|
|
|
| |
2 | Platen | FMCC0054701 | 50 km | |
|
|
|
|
NOTES: 1. The above values of the cutter life are obtained on condition that the periodically maintained cutter is used with TOSHIBA
2.The above values differ depending on the thickness and substances of the media to be used. When using the cutter to cut the labels, be sure to cut the backing paper. Failure to do this may cause the glue to stick to the cutter and shorten the cutter life.
8.Confirm each part adjustment. Make any necessary adjustments.
9.Conduct the following tests and make sure that there is no problem.
1)Print test with TOSHIBA
2)Paper skew
3)Print start position adjustment (Horizontal: media position, vertical: sensor adjustment/adjustment by issuing commands.)
4)Communication test
5)Abnormal noise
6)Confirm that there are not any other errors.
10.Close the top cover.