(13)Data string to be printed
Drawing data can be programmed by designating the number of digits after the symbol “=.” The maximum number of digits to be printed varies according to the types of bar codes. For codes, refer to the bar code table mentioned later.
(14)Link field No.
The link field No. can be programmed by designating it after the symbol “;”. After the link field No. is designated using the Format Command, the data string are linked by the Link Field Data Command to draw an image.
Up to 20 fields can be linked.
The following shows an example of linked fields on the two continuous labels.
[Format Command] |
|
|
|
|
|
|
[ESC] PC01; | ; 01 [LF] [NUL]: | Link field No. 1 is designated. | ||||
[ESC] PC02; | ; 03 [LF] [NUL]: | Link field No. 3 is designated. | ||||
[ESC] PC03; | ; 04 [LF] [NUL]: | Link field No. 4 is designated. | ||||
[ESC] XB01; | ; 03, 04 [LF] [NUL]: | Link fields No. 3 and No. 4 are | ||||
|
|
|
|
|
| designated. |
[ESC] PC04; | ; 02 [LF] [NUL]: | Link field No. 2 is designated. | ||||
[ESC] PC05; | ; 03 [LF] [NUL]: | Link field No. 3 is designated. | ||||
[ESC] PC06; | ; 04 [LF] [NUL]: | Link field No. 4 is designated. | ||||
[ESC] XB02; | ; 03, 04 [LF] [NUL]: | Link fields No. 3 and No. 4 are | ||||
|
|
|
|
|
| designated. |
[Data Command] |
|
|
|
| Designating link field No. | |
|
|
|
| |||
|
|
|
|
|
|
[ESC] RB; A [LF] B [LF] ABCD [LF] 001 [LF] [NUL]
Link field No. 4 Link field No. 3
Link field No. 2 Link field No. 1
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ABCD |
|
|
|
|
|
|
| A |
|
|
| ABCD |
|
|
|
|
|
| B |
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| ||||||||||||||||||
|
| ||||||||||||||||||
001 |
|
|
|
|
|
|
|
|
|
|
| 001 |
|
|
|
|
|
|
|
| |||||||||||||||||||
|
| ||||||||||||||||||
*ABCD001* |
|
|
| *ABCD001* | |||||||||||||||
|
| ||||||||||||||||||
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|