4.Loosen the four captive screws (1) at the corners of the 1010N-8M module (2) and carefully lift out the module disengaging it from the ribbon cable connecting it to the 1010N-2M module (3).

5.Leave the 1010N-2M module in place. Check to assure that the four corner standoffs (4) are securely threaded in place.

CAUTION: Do not connect a serial data cable to J1 on the 1015N-2M Modem Card or damage to the Modem Card and flowmeter may result.

ASSEMBLY (see Figure 5)

6.Remove the four captive screws (1) from the 1010N-8M module (2) in Step 4 above and discard. Install standoffs (5) from the mounting kit in the vacant positions, replacing the four 4-40 hex nuts to secure the standoff.

7.Install the 1010N-8M module (2) carefully engaging the ribbon cable connector (6) and dressing the cable for the best fit. Secure cable by threading the four standoffs (5) installed in Step 6 above with their mates on the 1010N-2M module (3).

START VIEW

(10) 1010N-8M I/O

Module Cover

(11) Captive Screw

(2) 1010N-8M I/O Module

(3) 1010N-2M

Analog Module

(1) Captive Screws

(4) Threaded Standoffs

System Computer Shield

Serial Data Cable - Not

 

used with 1015N-2M

 

Modem Card.

FINISH VIEW

 

(10) 1010N-8M I/O

 

 

Module Cover

 

 

(7) 1010N-8M I/O Module

 

 

(11) Captive Screw

 

 

(8) Cover Mount Standoff

 

 

(2) 1010N-8M I/O Module

 

 

(3) 1010N-2M

 

 

Analog Module

 

(5) Threaded Standoffs

 

 

 

System

(4) Threaded Standoffs

Computer

 

 

Shield

(9) 1010N-2M

 

(6) 1010N-8M

with Shield

 

Dress Ribbon Cable

Between Modules

Figure 5. Option 3 Installation (side view)

7

Image 11
Contents Field Manual Important Notice Manual Changes Table of Contents Option 3 Mounting KIT 1015N-2M-MK3 Introduction1015N-2M Modem Card Kits Option 1 Mounting KIT 1015N-2M-MK1 Option 2 Mounting KIT 1015N-2M-MK21010N Flowmeter System Requirements Technical SpecificationsPreliminary Installation Notes and Cautions 1015N-2M Modem Card Installation Option 1 Installation side view Refer to Installation Drawing 1015N-2M-MK-7 sheet 2 Refer to Installation Drawing 1015N-2M-MK-7 sheet 3 Option 3 Installation side view Telephone Line Connections Setting 1010N Flowmeter RS-232 ParametersWindows HyperTerminalTM Setup Communications ConfigurationAppendix a AT Command SET and S RegistersCommand Function Basic AT Commands AT CommandsSelect MNP 10 link negotiation at highest rate Registers Dial Modifiers AT Commands and S RegistersPercent AT% Commands AT Commands and ‘S RegistersAmpersand AT& Commands Atcommands and S Registers Appendix B Engineering Drawings Page Page