Appendix A1015N-2MFM-1A

“AT” COMMANDS and “S” REGISTERS

 

 

EXCLUSIVE TO THE PE2400

 

 

Dial Modifiers

 

 

 

Command

Factory Default

Parameters/Description

 

 

 

; (semicolon)

 

Return to Idle State. “ ; ” forces the modem to remain in the command state after dialing

 

 

a number without disconnecting. The semicolon must be placed at the end of the dial

 

 

command.

 

 

Parameters: none

@

 

WaIt for Quiet Answer Command. ” @ ” causes the modem to look for rings followed by

 

 

5 seconds of silence before processing the next symbol in the dialing string. The S7

 

 

register value determines the maximum wait time. If quiet answer is detected, the dial

 

 

modifiers following the command are executed. If busy is detected, the modem returns

 

 

a BUSY result code and goes to the hang-up process, aborting further execution of

 

 

commands.

 

 

Parameters: none

!

 

Flash Hook Command. “ ! ” causes the modem to go on-hook for 0.75 seconds.

 

 

Parameters: none

, (comma)

2 seconds

Pause Command. “ , “ causes the modem to pause for a specified time during dialing.

 

 

The S8 register value determines the pause time. Multiple commas may be used to

 

 

increase the pause time.

 

 

Parameters: none

0 to 9, A to D, #, *

 

Dial Digits/Characters. Characters 0 to 9, A, B, C, D, #, and * are valid. Characters A,

 

 

B, C, D, #, and * represent specific tone pairs and, therefore, can be used only when

 

 

tone dialing is selected.

 

 

Parameters: none

W

30 seconds

Wait for Dial Tone. W causes the modem to wait up to a specified time for the dial tone

 

 

to occur. The telephone number is dialed immediately upon dial tone detection. The

 

 

S7 register value determines the maximum wait time. If a busy signal is detected

 

 

instead of dial tone, the modem returns a BUSY result code and goes on-hook,

 

 

abandoning subsequent instructions on the command line.

 

 

Parameters: none

 

 

 

A-5

Image 18
Contents Field Manual Important Notice Manual Changes Table of Contents Option 2 Mounting KIT 1015N-2M-MK2 Introduction1015N-2M Modem Card Kits Option 1 Mounting KIT 1015N-2M-MK1 Option 3 Mounting KIT 1015N-2M-MK3Technical Specifications Preliminary Installation Notes and Cautions1010N Flowmeter System Requirements 1015N-2M Modem Card Installation Option 1 Installation side view Refer to Installation Drawing 1015N-2M-MK-7 sheet 2 Refer to Installation Drawing 1015N-2M-MK-7 sheet 3 Option 3 Installation side view Setting 1010N Flowmeter RS-232 Parameters Telephone Line ConnectionsCommunications Configuration Windows HyperTerminalTM SetupAT Command SET and S Registers Appendix aAT Commands Command Function Basic AT CommandsSelect MNP 10 link negotiation at highest rate Registers AT Commands and S Registers Dial ModifiersAT Commands and ‘S Registers Ampersand AT& CommandsPercent AT% Commands Atcommands and S Registers Appendix B Engineering Drawings Page Page