1015N-2MFM-1A
CAUTION: Do not connect a serial data cable to J1 on the 1015N-2M Modem Card or damage to the Modem Card and flowmeter may result.
4.Loosen the four captive screws (1) at the corners of the 1010N-2 module (7) and carefully lift out the module disengaging it from the connector on the 1010N-5 module (2).
5.Lift off the shield (3) covering the 1010N-5 module (2).
6.Leave the 1010N-5 module in place. Check to assure that the four corner standoffs (4) are securely threaded in place.
ASSEMBLY (see Figure 3)
7.Install shield (5) supplied with the 1015N-2M-MK1 mounting kit and cover the 1010N-5 module. Note: This shield replaces the shield removed in Step 5 above.
8.Remove the four captive screws (1) from the 1010N-2 module loosened in Step 4 above. Install standoffs (6) from mounting kit in the vacant positions.
9.Install the 1010N-2 module (7) carefully engaging connector P1 to the 1010N-5 module (2). Secure by threading the four standoffs (6) installed in Step 5 above with their mates on the 1010N-5 module.
10.Check for properly alignment of P1.
START VIEW
(11) 1010N-2 I/O Module Cover
(9) 1010N-2 I/O Module
(12) Captive Screw
(1)1010N-2 Captive Screws
(3)1010N-5 Analog Module Shield
(4)Threaded Standoffs
(2)1010N-5 Analog Module Assy
Serial Data Cable - Not used with 1015N-2M Modem Card.
FINISH VIEW
(11) 1010N-2 I/O |
Module Cover |
(9) 1015N-2M |
Modem Card |
(7) 1010N-2 |
I/O Module |
(12) Captive Screw |
(10) Cover Mount |
Standooff |
(6)Threaded Standoff
(5)1010N-5 Analog Module Shield
(4)Threaded Standoffs
(2) 1010N-5 Analog Module Assy
Figure 3. Option 1 Installation (side view)