Siemens 1015N-2MFM-1A manual Technical Specifications, 1010N Flowmeter System Requirements

Page 6

1015N-2MFM-1A

1015N-2M Modem Card

TB1 Network Connection

(2-Wire Hook Up)

Con 2 Network Connection (RJ11 Connector)

Captive

Screws (4)

Module ID Label

Top View

Side View

Figure 1. 1015N-2M Modem Card and Attaching Hardware

3.TECHNICAL SPECIFICATIONS

Interface:

RS-232

Supply Voltage:

5 volts DC

Supply Current:

48 mA

Modem Line Speeds:

2400, 1200 and 300 bps Asynchronous

DTE Rates:

2400, 1200, 300 bps

Modulation:

V.22bis, V.22, Bell 212A, Bell 103

Phone Line:

Dial Up or 2 Wire Leased Line

Extended Hayes Command Set Compatibility

Error Correction / Error Detection: None

Operating Environment:

-40 to 85 degrees C / 0 to 95% Humidity (non-condensing)

4.1010N FLOWMETER SYSTEM REQUIREMENTS

The System 1010N Flowmeter operating system must be revision level 2.0 or later for the 1015N-2M Modem Card to function properly. In addition, the 1015N-2M Modem Card requires 1010N system hardware of the following levels in order to work. Refer to the appropriate 1010N user manual installation/outline drawings for circuit board locations.

a.1010N-1-5 SysCom Version 3, Revision. D2 or Higher

b.1010N-2K3 I/O Board A2

c.1010N-8M-5 I/O Board A3

d.1010N-7K2 Analog I/O A2

5.PRELIMINARY INSTALLATION NOTES AND CAUTIONS

CAUTION: It is highly recommended that installation be done in a static free environment or damage to the 1015N-2M Modem Card may result.

NOTE: The 1015N-2M Modem will not function if the 1010 flowmeter RS-232 port is connected to the serial port of your PC.

NOTE: The 1015N-2M Modem will only transmit and receive data when used with direct phone line connections (see paragraph 5.3 below for communication connection options).

2

Image 6
Contents Field Manual Important Notice Manual Changes Table of Contents Option 2 Mounting KIT 1015N-2M-MK2 Introduction1015N-2M Modem Card Kits Option 1 Mounting KIT 1015N-2M-MK1 Option 3 Mounting KIT 1015N-2M-MK3Technical Specifications Preliminary Installation Notes and Cautions1010N Flowmeter System Requirements 1015N-2M Modem Card Installation Option 1 Installation side view Refer to Installation Drawing 1015N-2M-MK-7 sheet 2 Refer to Installation Drawing 1015N-2M-MK-7 sheet 3 Option 3 Installation side view Setting 1010N Flowmeter RS-232 Parameters Telephone Line ConnectionsCommunications Configuration Windows HyperTerminalTM SetupAT Command SET and S Registers Appendix aAT Commands Command Function Basic AT CommandsSelect MNP 10 link negotiation at highest rate Registers AT Commands and S Registers Dial ModifiersAT Commands and ‘S Registers Ampersand AT& CommandsPercent AT% Commands Atcommands and S Registers Appendix B Engineering Drawings Page Page