Siemens 1015N-2MFM-1A manual 1015N-2M Modem Card Installation, Flowmeter Access Cover Removal

Page 7

1015N-2MFM-1A

5.11015N-2M MODEM CARD INSTALLATION

WARNING: Set flowmeter and instrumentation power to OFF when inserting or removing the 1015N-2M Modem Card.

Before proceeding with the following installation procedures, identify the Module Loading option and installation drawing for your Modem Card (see Appendix A). The options are as follows:

a. Module Loading Option 1

1010N-5 with 1010N-2 in 1010N/DN Type System. Use Mounting Kit 1015N-2M-MK1. Refer to Installation Drawing 1015N-2M-MK-7 (sheet 1 of 3). Proceed to paragraph 5.1.1.

b. Module Loading Option 2

1010N-2 only in 1010N/DN Type System. Use Mounting Kit 1015N-2M-MK2. Refer to Installation Drawing 1015N-2M-MK-7 (sheet 2 of 3). Proceed to paragraph 5.1.2.

c. Module Loading Option 3

1010N-8M with 1010N-2M in 1010MN Type System. Use Mounting Kit 1015N-2M-MK3. Refer to Installation Drawing 1015N-2M-MK-7 (sheet 3 of 3). Proceed to paragraph 5.1.3.

5.1.1OPTION 1 INSTALLATION PROCEDURE (Mounting Kit 1015N-2M-MK1)1010N-5 Module with 1010N-2 Module in 1010N/DN Type System (Refer to Installation Drawing 1015N-2M-MK-7 sheet 1 of 3)

DISASSEMBLY (see Figure 2 and Figure 3)

1.Referring to Figure 1, open the 1010 NEMA flowmeter top cover by releasing the cover latch.

2.Place the power switch to the OFF position.

3.Loosen the captive thumbscrew securing the Access Cover and remove Access Cover.

Access Cover

Screw

1010N

Power Switich

Cover Latch

Figure 2. 1010N Flowmeter Access Cover Removal

3

Image 7
Contents Field Manual Important Notice Manual Changes Table of Contents Option 3 Mounting KIT 1015N-2M-MK3 Introduction1015N-2M Modem Card Kits Option 1 Mounting KIT 1015N-2M-MK1 Option 2 Mounting KIT 1015N-2M-MK2Preliminary Installation Notes and Cautions Technical Specifications1010N Flowmeter System Requirements 1015N-2M Modem Card Installation Option 1 Installation side view Refer to Installation Drawing 1015N-2M-MK-7 sheet 2 Refer to Installation Drawing 1015N-2M-MK-7 sheet 3 Option 3 Installation side view Telephone Line Connections Setting 1010N Flowmeter RS-232 ParametersWindows HyperTerminalTM Setup Communications ConfigurationAppendix a AT Command SET and S RegistersCommand Function Basic AT Commands AT CommandsSelect MNP 10 link negotiation at highest rate Registers Dial Modifiers AT Commands and S RegistersAmpersand AT& Commands AT Commands and ‘S RegistersPercent AT% Commands Atcommands and S Registers Appendix B Engineering Drawings Page Page