Dell Dimension 2100 technical specifications Microprocessor

Page 23

d.Connect the fan to the system board.

10.Replace the computer cover, and then reconnect your computer and peripherals to their electrical outlets and turn them on.

As the computer boots, it detects the presence of the new microprocessor and automatically changes the system configuration information in the system setup program.

11.Enter the system setup program, and confirm that the Processor Type and Processor Speed options correctly identify the newly installed microprocessor.

Microprocessor

1Microprocessor chip

2Release lever

3Microprocessor socket

NOTICE: Be careful not to bend any of the pins when you remove the microprocessor chip from its socket. Bending the pins can permanently damage the microprocessor chip.

Your microprocessor socket is a zero insertion force (ZIF) socket with a lever-type handle that secures the chip in (or releases it from) the socket.

1.To remove the chip, pull the microprocessor-socket release lever out to unlock it and then straight up until the chip is released.

2.Remove the chip from the socket. Leave the release lever extended so that the socket is ready for the new microprocessor.

NOTICE: Ground yourself by touching an unpainted metal surface on the back of the computer.

NOTICE: Be careful not to bend any of the pins when you unpack the microprocessor. Bending the pins can permanently damage the microprocessor.

3.Unpack the new microprocessor.

If any of the pins on the chip appear to be bent, obtain technical assistance.

4.Align the pin-1 corner of the microprocessor chip with the pin-1 corner of the microprocessor socket, as shown in the following figure.

NOTE: You must identify the pin-1 corner to correctly position the chip.

The pin-1 corner of the microprocessor is the beveled corner. The pin-1 corner of the socket, labeled "1," is the front-left corner of the socket as you face the back of the computer.

1Pin-1 corners of chip and socket aligned

5. Install the microprocessor chip in the socket (as shown in the preceding figure).

NOTICE: You must position the microprocessor chip correctly in the socket to avoid permanent damage to the chip and the computer when you turn on the system.

a.If the release lever on the microprocessor socket is not all the way out, move it to that position now.

b.With the pin-1 corners of the chip and socket aligned, align the pins on the chip with the holes in the socket.

c.Set the chip lightly in the socket and make sure that all pins are headed into the correct holes. Because your system uses a ZIF

Image 23
Contents Model MCM Dell Dimension 2100 System ReferenceDiagnostic Codes Definition Diagnostic CodesBack to Contents Diagnostic Codes Post Beep Codes System MessagesReseat the memory modules Post Beep CodesSystem Beep Codes Possible Cause System Messages System MessagesOperating system cannot be located on drive a or drive C Click Device Manager Click the Device Manager tabBack to Contents Front Panel Back Panel Controls and Lights Dell Dimension 2100 System ReferenceFront Panel Back PanelTypographical Conventions Conventions Dell Dimension 2100 System ReferenceTypographical Conventions Printed Documentation Online Documentation Documentation Dell Dimension 2100 System ReferencePrinted Documentation Online DocumentationBack to Contents Your Computer’s Drivers Drivers Dell Dimension 2100 System ReferenceUsing the Dell Dimension ResourceCD to Reinstall Drivers Back to Contents You have the recommended tools Precautionary MeasuresOverview Recommended ToolsCover Rotating the Power SupplyRotate the power supply back into place Remove the computer cover Tabs Inch Front Panel InsertUpper 3.5-Inch Drive InsertInch Drive Lower 3.5-Inch Floppy DriveHard Drive Remove the front cover Power Supply and Fan AssemblyControl Panel CardsMemory Remove the computer cover Rotate the power supplyConnector Remove and replace the microprocessor chip from the socket Heat SinkMicroprocessor System Board BatteryReplace the computer cover, and start the computer Remove the computer cover Remove the power supplyBack to Contents Expansion Bus System InformationVideo DrivesPorts Regulatory Notices PowerPhysical EnvironmentalCard Slot Default Dell-Installed Card PlacementIRQ Assignments IRQ Line System ResourceMain Screen System Setup Program Dell Dimension 2100 System ReferenceEntering the System Setup Program Advanced Screen Menu Options Function Advanced ScreenMain Screen Menu Options Function Displays the IDE Configuration submenu Base I/O Primary IDE Master SubmenuInterrupt ModePrimary IDE Master Submenu Options Diskette Configuration SubmenuEvent Log Configuration Submenu Diskette Configuration Submenu OptionsSecurity Screen Video Configuration SubmenuEvent Log Configuration Submenu Options Video Configuration Submenu Option FunctionSecurity Screen Options Function Boot ScreenBoot Screen Options Exit Screen Options Network DisabledExit Screen FloppyClearing Nvram Enter the system setup programInternal View Technical Overview Dell Dimension 2100 System ReferenceBack-Panel Features System Board Connectors and SocketsJumper Description System Board Configuration JumperPower Supply Jumper SettingVoltage Range Current DC Power Cables DC Power Connector Pin AssignmentsDC Power Connector P1 DC Voltage RangesDC Power Connectors P4, P5, and P6 Control Panel Connector J9F2 Pin AssignmentsDC Power Connector P2 DC Power Connector P3Back to Contents