Emerson XDF user manual

Page 59
Image 59
Contents Liebert XDF Page Table of Contents Cable Management Options Piping CONSIDERATIONS-WATER/GLYCOLMODELS onlyFilling the XDF with COOLANT-WATER or Glycol Electrical ConnectionsSpecifications MaintenanceTables Important Safety Instructions Indicates ground connection Glossary of SymbolsIndicates weight Hazardous Voltage PresentCondenser Coil 1 Backup Ventilation Air Intake CompressorEntry Point Condenser Air ICOM Controller Brazed Plate Condenser behind grille ICOM Controller Operational Overview Water/Glycol Cooled ModelReturn Line Female Condenser fanRemovable to reduce Height temporarilyDimensional data, self-contained, air cooled model Plate Connection 139.7mm176.5mm 47.6mmCable Entry Cutout 114mmEntry CutoutsDoors XDF ComponentsFrame EnclosureHeat Removal-Water/Glycol Cooled XDF Environmental ControlHeat Removal-Self-Contained, Air Cooled XDF Brazed Plate Condenser FrontRear Liebert iCOM controller Control-Liebert’s iCOM ControllerClosed-Loop Water System Coolant Source-Water/Glycol ModelsWater/Glycol Return Line Cooled Drycooler LoopGeneral Enclosure Options Power Options MP Advanced Power Strips and ControllersUninterruptible Power Supply Optional EquipmentUnloading the XDF Recommended Setup EquipmentInstallation InspectionFork Lift Handling the Unit While It is PackagedUnpack the XDF Right front corner detail controls side of XDF Removing the XDF from SkidRoll XDF off the shipping skid 915mm XDF Site Preparation36 915mm Voltage Input Requirements Voltage RequirementsModel Feet m 60Hz 50Hz Drycooler Installation-Water/Glycol Cooled ModelOptional condensate pump performance Maximum HeadRecommended equipment arrangement Equipment LayoutRear-Mount Rails-Position Frame and Enclosure ConfigurationsMounting Hardware Internal Mounting RailsQuick Door Removal Door-RemoveSide Panels-Remove and Replace Remove the DoorReplace a Panel Remove the Right PanelWater supply flow rates GeneralClosed Loop Water System Piping CONSIDERATIONS-WATER/GLYCOL Models onlyFreeze Protection-Coolant Type and Insulation Expansion Tanks, Fluid Relief Valves and Other DevicesCorrosion Protection Glycol supply flow rates Glycol SolutionsDrycooler Loop System Ethylene glycol concentrationsFilling the XDF with COOLANT-WATER or Glycol XDF Water/Glycol Cooled Unit VolumeVolume in standard Type L copper piping Preparing the System for FillingDashed line delineates equipment compartment Electrical ConnectionsCustomer Cable Entry Points Rear Route Input Power Cables Through the XDF’s Top Utility Power SupplyCable Management Options Cable Management ConsiderationsCable Management Top Cover and Back Cable AccessOptional Cable Management Channel Cable Tray Detail View Site Conditions XDF Startup Inspection ChecklistStartup Escape Key Down Arrow Key Starting the XDFOperation Environmental ControlICOM Components and Functions Icon Key Name Function Keyboard icons and functionsOK no Navigating Through the iCOM DisplayEntering the Password Accessing Menus and Settings Viewing DataChanging Operational Settings Icon Name Description User menu iconsHighlight the setting to be changed by pressing Enter Changing iCOM’s Display SettingsChanging the XDF’s Default Operating Temperature Operation With the Door Open XDF Compressor Backup Ventilation SystemUninterruptible Power Supply Troubleshooting Periodic MaintenanceMaintenance Monitoring SpecificationsPhysical specifications Self- Contained Water/Glycol Dimensions Air Cooled XDFSelf- Contained Water/Glycol Electrical Data Air Cooled XDF Electrical specificationsTotal heat rejection UPS performance data Optional Power SystemsRemote Monitoring Only MP Advanced Power Strip specificationsTypes Quan Port Remote Monitoring and Control Page That Ne tIti Ti n