Emerson XDF user manual Keyboard icons and functions, Icon Key Name Function

Page 46

Operation

Table 7

Keyboard icons and functions

 

 

 

Icon

Key Name

Function

 

 

 

 

On/Off Key

Controls the operational state of the cooling unit.

 

 

 

 

Alarm Key

Silences an alarm.

 

 

 

?

Help Key

Accesses integrated help menus.

 

 

 

 

ESC

ESCape Key

Returns to the previous display view.

 

 

 

 

Enter Key

Confirms all selections and selects icons or text.

 

 

 

 

Increase Key

Moves upward in a menu or increases the value of a selected parameter.

 

(Up Arrow)

 

 

 

 

 

 

Decrease Key

Moves downward in a menu or reduces the value of a selected parameter.

 

(Down Arrow)

 

 

 

 

 

 

Left and Right

Navigates through text and sections of the display.

 

Arrow Keys

 

 

Blinking Red—Active, unacknowledged alarm exists

Upper LED

Solid Red—Active, acknowledged alarm exists

Amber—Power is available to the unit, unit is NOT operating

Lower LED

Green—Power is available to the unit, unit is operating

40

Image 46
Contents Liebert XDF Page Table of Contents Electrical Connections Piping CONSIDERATIONS-WATER/GLYCOLMODELS onlyFilling the XDF with COOLANT-WATER or Glycol Cable Management OptionsMaintenance SpecificationsTables Important Safety Instructions Hazardous Voltage Present Glossary of SymbolsIndicates weight Indicates ground connectionEntry Point Condenser Air ICOM Controller Backup Ventilation Air Intake CompressorCondenser Coil 1 Operational Overview Water/Glycol Cooled Model Brazed Plate Condenser behind grille ICOM ControllerHeight temporarily Condenser fanRemovable to reduce Return Line FemaleDimensional data, self-contained, air cooled model 47.6mm 139.7mm176.5mm Plate ConnectionCutouts 114mmEntry Cable Entry CutoutEnclosure XDF ComponentsFrame DoorsHeat Removal-Self-Contained, Air Cooled XDF Environmental ControlHeat Removal-Water/Glycol Cooled XDF Rear FrontBrazed Plate Condenser Control-Liebert’s iCOM Controller Liebert iCOM controllerCoolant Source-Water/Glycol Models Closed-Loop Water SystemDrycooler Loop Water/Glycol Return Line CooledOptional Equipment Power Options MP Advanced Power Strips and ControllersUninterruptible Power Supply General Enclosure OptionsInspection Recommended Setup EquipmentInstallation Unloading the XDFUnpack the XDF Handling the Unit While It is PackagedFork Lift Removing the XDF from Skid Right front corner detail controls side of XDFRoll XDF off the shipping skid 36 915mm XDF Site Preparation915mm Voltage Requirements Voltage Input RequirementsMaximum Head Drycooler Installation-Water/Glycol Cooled ModelOptional condensate pump performance Model Feet m 60Hz 50HzEquipment Layout Recommended equipment arrangementInternal Mounting Rails Frame and Enclosure ConfigurationsMounting Hardware Rear-Mount Rails-PositionRemove the Door Door-RemoveSide Panels-Remove and Replace Quick Door RemovalRemove the Right Panel Replace a PanelPiping CONSIDERATIONS-WATER/GLYCOL Models only GeneralClosed Loop Water System Water supply flow ratesCorrosion Protection Expansion Tanks, Fluid Relief Valves and Other DevicesFreeze Protection-Coolant Type and Insulation Ethylene glycol concentrations Glycol SolutionsDrycooler Loop System Glycol supply flow ratesPreparing the System for Filling XDF Water/Glycol Cooled Unit VolumeVolume in standard Type L copper piping Filling the XDF with COOLANT-WATER or GlycolCustomer Cable Entry Points Electrical ConnectionsDashed line delineates equipment compartment Rear Utility Power Supply Route Input Power Cables Through the XDF’s TopCable Management Cable Management ConsiderationsCable Management Options Optional Cable Management Channel Cable AccessTop Cover and Back Cable Tray Detail View Startup XDF Startup Inspection ChecklistSite Conditions Starting the XDF Escape Key Down Arrow KeyICOM Components and Functions Environmental ControlOperation Keyboard icons and functions Icon Key Name FunctionNavigating Through the iCOM Display OK noAccessing Menus and Settings Viewing Data Entering the PasswordChanging Operational Settings User menu icons Icon Name DescriptionChanging the XDF’s Default Operating Temperature Changing iCOM’s Display SettingsHighlight the setting to be changed by pressing Enter Operation With the Door Open Uninterruptible Power Supply Backup Ventilation SystemXDF Compressor Maintenance Periodic MaintenanceTroubleshooting Self- Contained Water/Glycol Dimensions Air Cooled XDF SpecificationsPhysical specifications MonitoringTotal heat rejection Electrical specificationsSelf- Contained Water/Glycol Electrical Data Air Cooled XDF Optional Power Systems UPS performance dataTypes Quan Port Remote Monitoring and Control MP Advanced Power Strip specificationsRemote Monitoring Only Page Ti n Ne tIti That