APC AP8886, AP88XX, AP8861 manual Introduction, Product Features

Page 9

Introduction

Product Features

The APC by Schneider Electric Metered Rack Power Distribution Unit (PDU) may be used as a stand- alone, network-manageable power distribution device or up to 4 devices can be connected together with one network connection. The Rack PDU provides real-time remote monitoring of connected loads. User- defined alarms warn of potential circuit overloads.

Your unit comes with one terminator installed. It is not needed for stand-alone operation of this unit. To use Network Port Sharing between up to four units, a terminator must be installed in the In port at one end of the group and another on the Out port at the other end of the group.

You can manage a Rack PDU through its Web interface, its command line interface (CLI), StruxureWare, or Simple Network Management Protocol (SNMP). (To use the PowerNet MIB with an SNMP browser, see the PowerNet SNMP Management Information Base (MIB) Reference Guide, available at www.apc.com.) Rack PDUs have these additional features:

Peak load, and power and energy monitoring for all connected loads.

Voltage, current, and power monitoring for phases.

Current monitoring for outlet banks.

Configurable alarm thresholds that provide network and visual alarms to help avoid overloaded circuits.

Three levels of user access accounts: Administrator, Device User, and Read-Only User.

Event and data logging. The event log is accessible by Telnet, Secure CoPy (SCP), File Transfer Protocol (FTP), serial connection, or Web browser (using HTTPS access with SSL, or using HTTP access). The data log is accessible by Web browser, SCP, or FTP.

E-mail notifications for Rack PDU and system events.

SNMP traps, Syslog messages, and e-mail notifications based on the severity level or category of the Rack PDU and system events.

Security protocols for authentication and encryption.

Network Port Sharing: Up to four Rack PDUs can be connected using the In and Out ports so that only one network connection is necessary.

Note: The Rack PDU does not provide power surge protection. To ensure that the device is protected from power failure or power surges, connect the Rack PDU to an APC Uninterruptible Power Supply (UPS).

1

Metered Rack PDU User Guide

Image 9
Contents User Guide Contents Log on to the Command Line Interface Web Interface Logs Administration Notification Device IP Configuration Wizard Troubleshooting Introduction Product FeaturesTypes of User Accounts Access Priorities for Logging onNetwork Port Sharing Watchdog FeaturesGetting Started TCP/IP configuration methods Establish Network SettingsDhcp and Bootp configuration INI file utilityOption 43 = 01 04 31 41 50 Command Line Interface Recovering from a Lost Password Function Rack PDU Front PanelFunction Display Tree Example Display Tree Example Network Status LED Load indicator LEDCondition Description 10/100 LEDAbout the Command Line Interface Command Line InterfaceLog on to the Command Line Interface Remote access to the command line interfaceAbout the Main Screen Local access to the command line interfaceIPv4 IPv6 Description Only Using the Command Line InterfaceDescription Command SyntaxCode Message Command Response CodesAlarmcount Network Management Card Command DescriptionsAbout Option Arguments DescriptionBoot Option Argument DescriptionClrrst Console Delete DateArgument Description DirEventlog DnsExit FormatHelp Option Argument DefinitionNetstat NtpPortSpeed PingPrompt QuitRadius RebootResetToDef Snmp, snmpv3System Tcpip6 TcpipWeb UserXferStatus XferININetwork Port Sharing Commands Device Command DescriptionsBkLowLoad BkNearOverBkOverLoad BkReadingDevLowLoad DevOverLoad DevNearOverDevReading Argument DefinitionHumLow HumMinHumReading PhLowLoad PhNearOverPhOverLoad PhReading SensorName ProdInfoTempHigh TempMaxTempReading Whoami Web Interface Supported Web BrowsersLogging On to the Web Interface URL address formats Error Message Browser Cause of the ErrorSymbol Description Web Interface FeaturesTabs Device status iconsQuick Links Other Web interface featuresNetwork Port Sharing on the Web Interface Group Control using Network Port SharingMetered Rack PDU User Guide Alarm Status view About the Home TabOverview view Device Management Configuring Load ThresholdsAbout the Device Manager Tab Viewing the Load Status and Peak LoadResetting Peak Load and kWh Configure the Name and Location of the Rack PDUEnvironment Configure Temperature and Humidity SensorsLogs Use the Event and Data LogsEvent log Example event log Rack PDU 4 Device low load Path Logs Data options Data logParameter Description Scp username@hostnameoripaddressdata.txt ./data.txt How to use FTP or SCP to retrieve log filesSetting user access Administration SecurityAuthentication Local UsersRadius Radius Setting DefinitionSummary of the configuration procedure Configure the Radius ServerConfiguring a Radius server on Unix with shadow passwords Supported Radius serversInactivity Timeout TCP/IP and Communication Settings Administration Network FeaturesTCP/IP settings Setting DescriptionAPC Cookie. Tag 1, Len 4, Data 1APC Dhcp response optionsPing Response Port SpeedQuery Type Selected Query Question to Use DNSWeb Option DescriptionStatus Telnet 152.214.12.1145000 telnet 152.214.12.114 ConsoleSnmp SNMPv1 SNMPv3 FTP Server Configuring event actions Administration NotificationEvent Actions Types of notificationMetered Rack PDU User Guide Mail notification Active, Automatic, Direct NotificationSend a test message to a configured recipient Snmp Trap Test Snmp trapsRemote Monitoring Service Setting DefinitionSyslog Informational is mapped to Info Identification Administration General OptionsSet the Date and Time ModeDaylight saving Use an .ini FileReset the Rack PDU Event Log and Temperature UnitsChange the default temperature scale Color-code event log textAbout the Rack PDU Configure LinksDevice IP Configuration Wizard Capabilities, Requirements, and InstallationUse the Wizard Configure or reconfigure the TCP/IP settings locally Select Remotely over the network, and click NextSelect Locally through the serial port, and click Next Summary of the procedure How to Export Configuration SettingsContents of the .ini file Retrieving and Exporting the .ini FileDetailed procedures Ftp open ipaddress Event and its error messages Upload Event and Error MessagesMessages in config.ini Errors generated by overridden valuesFile Transfers How to Upgrade FirmwareFirmware File Transfer Methods Benefits of upgrading firmwareUse FTP or SCP to upgrade one Rack PDU Using the Firmware Upgrade UtilityUse Xmodem to upgrade one Rack PDU How to upgrade multiple Rack PDUs Using the Firmware Upgrade Utility for multiple upgradesUsing a USB flash drive to upgrade one Rack PDU Firmware Module Binary File Verify the version numbers of installed firmware Verifying Upgrades and UpdatesVerify the success or failure of the transfer Last Transfer Result codesTroubleshooting Rack PDU Access ProblemsProblem Solution Network Management Card Command Descriptions Appendix a List of Supported CommandsSets manual IPv6 address Device Command Descriptions 990-3429D-001 10/2012 APC Worldwide Customer Support

AP8886, AP88XX, AP8861 specifications

The APC AP8861, part of the AP88XX series, is a highly versatile and advanced power distribution unit (PDU) designed to meet the growing demands of data centers and IT environments. This series encompasses state-of-the-art technologies and features designed to enhance both operational efficiency and reliability.

The AP8861 model is particularly recognized for its modular design, allowing for easy scaling and expansion as data center needs evolve. With a variety of outlet configurations, it can accommodate numerous devices while optimizing power management. The device supports both standard and high-density power distribution, making it suitable for diverse environments, from small server rooms to large-scale data centers.

One of the hallmark features of the AP8861 is its built-in network management capabilities. It allows for real-time monitoring of power consumption, ensuring optimal load balancing and helping prevent overload situations. The device incorporates environmental monitoring through temperature and humidity sensors, enabling administrators to proactively manage operating conditions and mitigate risks to sensitive equipment.

The AP88XX series features advanced Surge Protection, which guards against electrical surges that can damage connected equipment. This is a critical consideration in data centers where the integrity of sensitive electronics is paramount. Additionally, the series supports remote management, allowing IT personnel to monitor and control power distribution from anywhere in the world. This function enhances operational flexibility and facilitates rapid responses to power-related issues.

Another significant characteristic of the AP8861 is its compatibility with APC's software solutions. Integrating seamlessly with IT management platforms enables deeper insights and analytics, leading to informed decision-making regarding power usage and equipment reliability.

The device boasts a high-efficiency design, contributing to reducing overall energy costs. The capability to customize alarm settings for power events and environmental factors further enhances proactive management of the data center environment.

In summary, the APC AP8861 and the entire AP88XX series are engineered for robust performance, enhanced control, and adaptability in power distribution management. Packed with advanced features, this series offers solutions that help businesses optimize their data centers while ensuring maximum uptime and equipment protection, thereby supporting the ever-increasing demands placed on modern IT infrastructures.