APC AP8861, AP8886, AP88XX manual Example event log Rack PDU 4 Device low load

Page 59

To filter the log (Logs > Events > log):

Filtering the log by date or time: To display the entire event log, or to change the number of days or weeks for which the log displays the most recent events, select Last. Select a time range from the drop-down menu, then click Apply. The filter configuration is saved until the Rack PDU restarts.

To display events logged during a specific time range, select From. Specify the beginning and ending times (using the 24-hour clock format) and dates for which to display events, then click Apply. The filter configuration is saved until the Rack PDU restarts.

Filtering the log by event: To specify the events that display in the log, click Filter Log. Clear the checkbox of an event category or alarm severity level to remove it from view. Text at the upper right corner of the event log page indicates that a filter is active.

As Administrator, click Save As Default to save this filter as the default log view for all users. If you do not click Save As Default, the filter is active until you clear it or until the Rack PDU restarts.

To remove an active filter, click Filter Log, then Clear Filter (Show All).

Note: Events are processed through the filter using OR logic.

Events that you do not select from the Filter By Severity list never display in the filtered event log, even if the event occurs in a category you selected from the Filter by Category list. Events that you do not select from the Filter by Category list never display in the filtered event log, even if devices in the category enter an alarm state you selected from the Filter by Severity list.

To delete the log (Logs > Events > log):

To delete all events recorded in the log, click Clear Log on the Web page that displays the log. Deleted events cannot be retrieved. To disable the logging of events based on their assigned severity level or their event category, see “Configuring by event” on page 70.

To configure reverse lookup (Logs > Events > reverse lookup):

Reverse lookup is disabled by default. Enable this feature unless you have no DNS server configured or have poor network performance because of heavy network traffic.

With reverse lookup enabled, when a network-related event occurs, both the IP address and the domain name for the networked device associated with the event are logged in the event log. If no domain name entry exists for the device, only its IP address is logged with the event. Since domain names generally change less frequently than IP addresses, enabling reverse lookup can improve the ability to identify addresses of networked devices that are causing events.

To resize the event log (Logs > Events > size):

By default, the event log stores 400 events. You can change the number of events the log stores. When you resize the event log, all existing log entries are deleted. To avoid losing log data, use FTP or SCP to retrieve the log before you enter a new value in the Event Log Size field. See “How to use FTP or SCP to retrieve log files” on page 54.

When the log is full, the older entries are deleted.

Network Port Sharing Event Logs and Traps.

Rack PDU events from guest PDUs are sent to the host PDU for inclusion into its log. The log entry will include the Display ID of the unit that the event occurred on.

These events are then handled the same as local events from the host PDU. Therefore alarms, SNMP traps, e-mails, Syslog, etc will support Rack PDU events and alarms from all Rack PDUs in a group.

Example event log: Rack PDU 4: Device low load.

Note: System events will only be logged for the host PDU. System events from guest PDUs will not be logged on the host PDU.

51

Metered Rack PDU User Guide

Image 59
Contents User Guide Contents Log on to the Command Line Interface Web Interface Logs Administration Notification Device IP Configuration Wizard Troubleshooting Introduction Product FeaturesTypes of User Accounts Access Priorities for Logging onNetwork Port Sharing Watchdog FeaturesGetting Started INI file utility Establish Network SettingsTCP/IP configuration methods Dhcp and Bootp configurationOption 43 = 01 04 31 41 50 Command Line Interface Recovering from a Lost Password Function Rack PDU Front PanelFunction Display Tree Example Display Tree Example 10/100 LED Load indicator LEDNetwork Status LED Condition DescriptionRemote access to the command line interface Command Line InterfaceAbout the Command Line Interface Log on to the Command Line InterfaceAbout the Main Screen Local access to the command line interfaceIPv4 IPv6 Description Only Using the Command Line InterfaceDescription Command SyntaxCode Message Command Response CodesOption Arguments Description Network Management Card Command DescriptionsAlarmcount AboutClrrst BootOption Argument Description Console Dir DateDelete Argument DescriptionFormat DnsEventlog ExitNtp Option Argument DefinitionHelp NetstatQuit PingPortSpeed PromptRadius RebootSystem ResetToDefSnmp, snmpv3 Tcpip6 TcpipWeb UserXferStatus XferINIBkNearOver Device Command DescriptionsNetwork Port Sharing Commands BkLowLoadDevLowLoad BkOverLoadBkReading Argument Definition DevNearOverDevOverLoad DevReadingHumReading HumLowHumMin PhOverLoad PhLowLoadPhNearOver PhReading SensorName ProdInfoTempReading TempHighTempMax Whoami Logging On to the Web Interface Web InterfaceSupported Web Browsers URL address formats Error Message Browser Cause of the ErrorDevice status icons Web Interface FeaturesSymbol Description TabsQuick Links Other Web interface featuresNetwork Port Sharing on the Web Interface Group Control using Network Port SharingMetered Rack PDU User Guide Overview view Alarm Status viewAbout the Home Tab Viewing the Load Status and Peak Load Configuring Load ThresholdsDevice Management About the Device Manager TabResetting Peak Load and kWh Configure the Name and Location of the Rack PDUEnvironment Configure Temperature and Humidity SensorsEvent log LogsUse the Event and Data Logs Example event log Rack PDU 4 Device low load Path Logs Data options Data logParameter Description Scp username@hostnameoripaddressdata.txt ./data.txt How to use FTP or SCP to retrieve log filesLocal Users Administration SecuritySetting user access AuthenticationRadius Radius Setting DefinitionSupported Radius servers Configure the Radius ServerSummary of the configuration procedure Configuring a Radius server on Unix with shadow passwordsInactivity Timeout Setting Description Administration Network FeaturesTCP/IP and Communication Settings TCP/IP settingsAPC Cookie. Tag 1, Len 4, Data 1APC Dhcp response optionsPing Response Port SpeedQuery Type Selected Query Question to Use DNSStatus WebOption Description Telnet 152.214.12.1145000 telnet 152.214.12.114 ConsoleSnmp SNMPv1 SNMPv3 FTP Server Types of notification Administration NotificationConfiguring event actions Event ActionsMetered Rack PDU User Guide Mail notification Active, Automatic, Direct NotificationSend a test message to a configured recipient Snmp Trap Test Snmp trapsSyslog Remote Monitoring ServiceSetting Definition Informational is mapped to Info Mode Administration General OptionsIdentification Set the Date and TimeDaylight saving Use an .ini FileColor-code event log text Event Log and Temperature UnitsReset the Rack PDU Change the default temperature scaleAbout the Rack PDU Configure LinksUse the Wizard Device IP Configuration WizardCapabilities, Requirements, and Installation Select Locally through the serial port, and click Next Configure or reconfigure the TCP/IP settings locallySelect Remotely over the network, and click Next Retrieving and Exporting the .ini File How to Export Configuration SettingsSummary of the procedure Contents of the .ini fileDetailed procedures Ftp open ipaddress Errors generated by overridden values Upload Event and Error MessagesEvent and its error messages Messages in config.iniBenefits of upgrading firmware How to Upgrade FirmwareFile Transfers Firmware File Transfer MethodsUse FTP or SCP to upgrade one Rack PDU Using the Firmware Upgrade UtilityUse Xmodem to upgrade one Rack PDU Using a USB flash drive to upgrade one Rack PDU How to upgrade multiple Rack PDUsUsing the Firmware Upgrade Utility for multiple upgrades Firmware Module Binary File Last Transfer Result codes Verifying Upgrades and UpdatesVerify the version numbers of installed firmware Verify the success or failure of the transferProblem Solution TroubleshootingRack PDU Access Problems Network Management Card Command Descriptions Appendix a List of Supported CommandsSets manual IPv6 address Device Command Descriptions 990-3429D-001 10/2012 APC Worldwide Customer Support

AP8886, AP88XX, AP8861 specifications

The APC AP8861, part of the AP88XX series, is a highly versatile and advanced power distribution unit (PDU) designed to meet the growing demands of data centers and IT environments. This series encompasses state-of-the-art technologies and features designed to enhance both operational efficiency and reliability.

The AP8861 model is particularly recognized for its modular design, allowing for easy scaling and expansion as data center needs evolve. With a variety of outlet configurations, it can accommodate numerous devices while optimizing power management. The device supports both standard and high-density power distribution, making it suitable for diverse environments, from small server rooms to large-scale data centers.

One of the hallmark features of the AP8861 is its built-in network management capabilities. It allows for real-time monitoring of power consumption, ensuring optimal load balancing and helping prevent overload situations. The device incorporates environmental monitoring through temperature and humidity sensors, enabling administrators to proactively manage operating conditions and mitigate risks to sensitive equipment.

The AP88XX series features advanced Surge Protection, which guards against electrical surges that can damage connected equipment. This is a critical consideration in data centers where the integrity of sensitive electronics is paramount. Additionally, the series supports remote management, allowing IT personnel to monitor and control power distribution from anywhere in the world. This function enhances operational flexibility and facilitates rapid responses to power-related issues.

Another significant characteristic of the AP8861 is its compatibility with APC's software solutions. Integrating seamlessly with IT management platforms enables deeper insights and analytics, leading to informed decision-making regarding power usage and equipment reliability.

The device boasts a high-efficiency design, contributing to reducing overall energy costs. The capability to customize alarm settings for power events and environmental factors further enhances proactive management of the data center environment.

In summary, the APC AP8861 and the entire AP88XX series are engineered for robust performance, enhanced control, and adaptability in power distribution management. Packed with advanced features, this series offers solutions that help businesses optimize their data centers while ensuring maximum uptime and equipment protection, thereby supporting the ever-increasing demands placed on modern IT infrastructures.