Connect Components to the Unit

Power-Saving Master and Controlled outlets

The G50B-20A2 reduces power consumption by disconnecting utility power to devices that are not in use. When a device is in sleep or standby mode, it still uses power; when the G50B-20A2 turns off the power to an outlet, it conserves this power.

1.Before connecting components to the unit, determine which components will utilize the Master and Controlled outlets.

Connect a master device such as a TV to the Master outlet.

Connect peripheral devices such as amplifiers, DVD players, or sub-woofers to the Controlled outlets.

2.Connect components to the outlets on the back panel of the unit.

3.Configure the G50B-20A2 to recognize the master outlet. See “Configure Master and Controlled outlets” on page 6.

Always On, Switched, and Delayed outlets

Before connecting components to the unit, determine which components will utilize the ALWAYS ON outlets, the SWITCHED outlet, and the DELAY outlets. Then, connect components to the outlets on the back panel of the unit.

Always On outlet. The ALWAYS ON outlets supply power to the connected components, even if the unit is turned off. If A/C power is lost, and then re-applied to the unit, the component connected to the ALWAYS ON outlet will turn on immediately and return to the status of operation before the power outage.

Switched outlet. The SWITCHED outlet supplies power to the connected equipment while the unit is on. If the unit shuts off, it will not supply power to equipment connected to the SWITCHED outlet. If A/C power is lost, and then re-applied to the unit, equipment connected to the SWITCHED outlet will turn on immediately and return to the status of operation before the power outage.

Delay outlets. The unit has five delayed outlets. When the unit is turned on, power is immediately applied to the SWITCHED outlet (power was already being supplied to the ALWAYS ON outlets, even though the unit was off). Then, power is applied to each of the DELAYED outlets in sequence, DELAY 1 first, through DELAY 4.

When the unit is turned off, power is disconnected from the delayed outlets in reverse order.

Use the display interface to customize the delay times.

4

APC A/V G-Type Rack Power Filter: Installation

Image 8
Contents Installation and Operation Page Contents Specifications Safety General InformationOverview InventoryComponents Front viewRear view Removable FlashlightConnect A/C Power InstallationInstall the Unit Connect Components to the Unit Power-Saving Master and Controlled outletsAlways On, Switched, and Delayed outlets Operation Basic FunctionsFront panel buttons Display interface LEDsConfigure the Unit Display Interface Menus Lock the unitShut down the unit Status menuSetup menu Power Threshold 10 W Tracking Power Successfully Save screen as default Troubleshooting Common problems and solutionsOverload indicator is illuminated Wiring OK indicator is not illuminatedSpecifications Contact APC APV Technical Support WarrantyInformación general IntroducciónInventario SeguridadComponentes Vista delanteraVista posterior Linterna desmontableConexión al suministro de energía de CA InstalaciónInstalación de la unidad Conexión de los componentes a la unidad Funcionamiento Funciones básicasBotones del panel delantero Indicadores luminosos de la interfaz de pantallaSuministrando a DELAY1 Configuración de la unidad Configuración del idiomaTomacorrientes de retardo de secuencia Visualización del estado de la unidadMenús de la interfaz de pantalla Tomacorrientes de detección de corrienteBloqueo de la unidad Desconexión de la unidadMenú Configuración Versión de firmwareAtenuador DE Indicadores Atenuar Guardado de pantalla como predeterminada Resolución de problemas Problemas comunes y solucionesLa unidad no se enciende El indicador luminoso Overload sobretensión está encendidoEspecificaciones Informations générales AperçuInventaire SécuritéComposants Vue avantVue arrière Lampe de poche amovibleInstallation de lappareil Installer lappareil sur une surface planeInstaller lappareil dans un rack ou dans un châssis Connexion de lalimentation secteurBranchement de périphériques à lappareil Prises toujours alimentées, commutées et à délaiFonctionnement Fonctions de baseBoutons de la façade Témoins lumineux de linterface daffichageTémoin Allumé Éteint Lumineux Configuration de lappareil Choix de la langueSéquence des prises à délai Affichage de létat de lappareilAffichage des menus de linterface Prises à détection de courantVerrouillage de lappareil Extinction de lappareilMenu Configuration Version du micrologicielSuivi Dalimentation Terminé Enregistrer lécran par défaut Problèmes habituels et solutions DépannageLappareil ne sallume pas Le témoin de surcharge est alluméContacter le service de soutien technique dAPC APV Garantie SpécificationsPage APC Worldwide Customer Support 990-3790B 05/2010