APC G50B-20A2 manual Operation, Basic Functions, Front panel buttons, Display interface LEDs

Page 9

Operation

Basic Functions

Note: The LCD display interface screen and LEDs can be dimmed, using the Setup menu. Press any button on the front panel of the unit to illuminate the display screen and the LEDs.

Front panel buttons

Utility Source 122V 60Hz

Use the display interface on the front of the G50B-20A2 to configure and operate the unit.

Power. Push to apply power to the unit or to shut off power to the unit.

Status. Push to display the current status of the unit, including the current input/output voltage.

Setup. Push to scroll through the setup menus.

Up/Down. Push to change values (Setup menu) and browse menu pages (Status menu).

Display interface LEDs

There are eleven LEDs on the display interface.

LED

Illuminated

Not Illuminated

 

 

 

POWER ON

The unit is supplied with utility

There is no input utility power.

 

power.

 

LINE OK The utility power is within acceptable range, 92 V to 140 V.

The input voltage from utility power is outside the acceptable range and the unit has disconnected from utility power to protect the connected equipment.

PROTECTION The unit is protecting all connected

WORKING equipment.

The unit is not providing power protection. See Troubleshooting and contact APC Technical Support immediately.

WIRING OK The unit is functioning properly.

There is a problem with the building wiring. Contact a certified electrician.

OVERLOAD

The unit is overloaded. Disconnect

The unit is functioning properly.

 

some connected components.

 

 

Contact APC Technical Support.

 

 

 

DELAY 1

Power is being supplied to DELAY1. Power is not being supplied to DELAY1.

 

 

 

DELAY 2A

Power is being supplied to

Power is not being supplied to DELAY2A.

 

DELAY2A.

 

DELAY 2B Power is being supplied to

DELAY2B.

Power is not being supplied to DELAY2B.

DELAY 3

Power is being supplied to DELAY3.

Power is not being supplied to DELAY3.

DELAY 4

Power is being supplied to DELAY4.

Power is not being supplied to DELAY4.

 

 

 

SWITCHED

Power is being supplied to the

Power is not being supplied to the SWITCHED outlet.

 

SWITCHED outlet.

 

APC A/V G-Type Rack Power Filter: Operation

5

Image 9
Contents Installation and Operation Page Contents Specifications General Information SafetyOverview InventoryFront view ComponentsRear view Removable FlashlightInstallation Install the UnitConnect A/C Power Power-Saving Master and Controlled outlets Always On, Switched, and Delayed outletsConnect Components to the Unit Basic Functions OperationFront panel buttons Display interface LEDsConfigure the Unit Lock the unit Display Interface MenusShut down the unit Status menuSetup menu Power Threshold 10 W Tracking Power Successfully Save screen as default Common problems and solutions TroubleshootingOverload indicator is illuminated Wiring OK indicator is not illuminatedContact APC APV Technical Support Warranty SpecificationsIntroducción Información generalInventario SeguridadVista delantera ComponentesVista posterior Linterna desmontableInstalación Instalación de la unidadConexión al suministro de energía de CA Conexión de los componentes a la unidad Funciones básicas FuncionamientoBotones del panel delantero Indicadores luminosos de la interfaz de pantallaSuministrando a DELAY1 Configuración del idioma Configuración de la unidadTomacorrientes de retardo de secuencia Visualización del estado de la unidadTomacorrientes de detección de corriente Menús de la interfaz de pantallaBloqueo de la unidad Desconexión de la unidadVersión de firmware Menú ConfiguraciónAtenuador DE Indicadores Atenuar Guardado de pantalla como predeterminada Problemas comunes y soluciones Resolución de problemasLa unidad no se enciende El indicador luminoso Overload sobretensión está encendidoEspecificaciones Aperçu Informations généralesInventaire SécuritéVue avant ComposantsVue arrière Lampe de poche amovibleInstaller lappareil sur une surface plane Installation de lappareilInstaller lappareil dans un rack ou dans un châssis Connexion de lalimentation secteurPrises toujours alimentées, commutées et à délai Branchement de périphériques à lappareilFonctions de base FonctionnementBoutons de la façade Témoins lumineux de linterface daffichageTémoin Allumé Éteint Lumineux Choix de la langue Configuration de lappareilSéquence des prises à délai Affichage de létat de lappareilPrises à détection de courant Affichage des menus de linterfaceVerrouillage de lappareil Extinction de lappareilVersion du micrologiciel Menu ConfigurationSuivi Dalimentation Terminé Enregistrer lécran par défaut Dépannage Problèmes habituels et solutionsLappareil ne sallume pas Le témoin de surcharge est alluméSpécifications Contacter le service de soutien technique dAPC APV GarantiePage 990-3790B 05/2010 APC Worldwide Customer Support