EPSON Perfection 610 | Revision B |
1.6 Error Indications
Refer to Section 1.5 for the error indications.
COMMAND ERROR
Cause: | Undefined command is detected. | |
Disposition: | The scanner ignores a wrong command and | |
|
| parameter(s), so it keeps the current settings or |
|
| default value effective. The scanner sends |
|
| NACK and waits for the next command and |
|
| parameter(s). |
Indicator: | No effect | |
Remedy: | Error condition is cleared when the scanner | |
|
| receives a correct command. |
|
| |
COMMUNICATION | ERROR | |
|
| |
Cause: | Wrong procedure is detected in the interface | |
|
| communication. |
|
| USB cable was removed during communication. |
Disposition: | The scanner stops the ongoing job. | |
Indicator: | The lamp starts blinking. (The lamp goes off in | |
|
| 30 minutes.) |
Remedy: | Turn the scanner off and then back on. | |
| Connect the USB cable again. | |
Acceptable command: None | ||
|
|
|
FATAL | ERROR |
|
|
| |
Cause: | The lamp is broken. | |
|
| The scanner is turned on before the |
|
| transportation lock is released. |
| System breakdown | |
Disposition: | The scanner stops the ongoing job. |
Indicator: | The lamp starts blinking. (The lamp goes off after |
| 30 minutes.) |
| The lamp does not light up when it has blown. |
Remedy: | (After the cause of the error is removed) |
| Turn the scanner off and then back on. |
| Connect the USB cable again. |
Receiving of ESC@ |
Acceptable command: [ESC F, ESC f, ESC @]
Product Description | Error Indications | 13 |