10.Inserting a standard screw driver from the back, remove the FFC metal clamp.
Carriage Unit
FFC Metal Clamp
FFC Cable
Guide Tabs
Connector
Figure 4-19. FFC Metal Clamp and FFC Removal
11.Release the FFC (white) from the connector and the two guide tabs in the Carriage Unit, and then remove the Carriage Unit.
Carriage Unit
Figure 4-20. Carriage Unit