EPSON Perfection 610 | Revision B |
1.4 Control Codes
The command level of this scanner is
Table 1-3. Control Codes
Category |
| Command Name |
| Code |
|
|
|
|
|
|
| Request Identity |
| ESC I |
|
|
|
|
|
|
| Request Identity 2 |
| ESC i |
|
|
|
|
|
Execute Command |
| Request Status |
| ESC F |
|
|
|
| |
| Request Extended Status |
| ESC f | |
|
|
| ||
|
|
|
|
|
|
| Start Scanning |
| ESC G |
|
|
|
|
|
|
| Request Push Button Status |
| ESC! |
|
|
|
|
|
|
| Set Data Format |
| ESC D i |
|
|
|
|
|
Set Data Format |
| Set Resolution |
| ESC R n1 n2 |
|
|
|
| |
| Set Scanning Area |
| ESC A n1 n2 n3 n4 | |
|
|
| ||
|
|
|
|
|
|
| Set Color |
| ESC C i |
|
|
|
|
|
Image Correction |
| Set Gamma Correction |
| ESC Z i |
|
|
|
| |
| Download Gamma Table |
| ESC z i d[256] | |
|
|
| ||
|
|
|
|
|
|
| Set Color Correction Factor |
| ESC m d[9] |
|
|
|
|
|
|
| Set Threshold |
| ESC t i |
|
|
|
|
|
Auxiliary |
| Set Scanning Mode |
| ESC g i |
|
|
|
|
|
|
| Initialize |
| ESC @ |
|
|
|
|
|
|
| Set Line Counter |
| ESC d i |
|
|
|
|
|
|
| Normal Response |
| ACK |
|
|
|
|
|
Control |
| Abnormal Response |
| NACK |
|
|
|
| |
| Abort Scanning |
| CAN | |
|
|
| ||
|
|
|
|
|
|
| Header |
| STX |
|
|
|
|
|
1.5 Lamp Descriptions
Since this scanner does not have any LED indicator, it shows the various conditions by turning on/off or blinking the lamp. Conditions indicated by the lamp are as listed below:
Lamp: On
The scanner is in a normal condition. Lamp: Blinking
The scanner is turned on before the transportation screw is unlocked.
Communication error
Fatal error except for lamp break has occurred.
NOTE: The lamp goes off after 30 minutes.
Lamp: Off
Power save mode (Command is not received for 10 minutes.) Power is not supplied.
The lamp has blown out.
The lamp was left blinking for 30 minutes.
Product Description | Control Codes | 12 |