2.1.3 Power Supply Circuit
Power supply circuit board in this scanner generates direct current necessary for driving the controller board and scanner engine.
See Table
Table
Specification |
| Unit Part No. |
| Fuse |
|
|
|
|
|
100 |
| 2031592 |
| 2.5 A / 125 VAC |
|
|
|
|
|
220 |
| 2031593 |
| T2.5AH / 250 VAC |
|
|
|
|
|
Table 2-2. Protection Circuits for Output Voltages/Currents
Output |
| Output |
|
| Over Current Protection |
|
| Over Voltage Protection |
Voltage |
| Current |
|
|
|
| ||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
5 VDC |
| 1.2A |
| • | The current is held 1A or less by the |
| • | Shut down. |
|
|
|
|
|
| • To restore, turn the scanner off and | ||
|
|
|
| • | Recovers automatically*. |
|
| then back on. |
|
|
|
|
|
|
| • The protection circuit becomes active | |
|
|
|
|
|
|
|
| when the voltage rises to 5.5 - 7.5 |
|
|
|
|
|
|
|
| VDC. |
|
|
|
|
|
|
|
|
|
12 VDC |
| 0.2A |
| • | The current is held 0.5 or less by the |
| • | Shut down. |
|
|
|
|
|
| • To restore, turn the scanner power off | ||
|
|
|
|
| generator. |
|
| and then back on. |
|
|
|
| • | Recovers automatically*. |
| • The protection circuit becomes active | |
|
|
|
|
|
|
|
| when the voltage rises to 14 |
24 VDC |
| 0.7A |
| • | Shut down. |
| • | Shut down. |
|
|
|
| • To restore, turn the scanner power off |
| • To restore, turn the scanner power off | ||
|
|
|
|
| and then back on. |
|
| and then back on. |
|
|
|
|
|
|
| • The protection circuit becomes active | |
|
|
|
|
|
|
|
| when the voltage rises to 28 |
|
|
|
|
|
|
|
|
|
*: Recovers within 5 minutes.
NOTE: If any of the outputs is shut down, all the other outputs are also shut down.