Metrologic Instruments MX003, MS6130 manual

Page 14

CONFIGURATION OF THE “MX” TO THE RS-232, LIGHT PEN OR KEYBOARD WEDGE HOST SYSTEM

To perform matching procedure refer to page 18.

The light pen, RS-232 and Keyboard Wedge parameters marked with an asterisk ( * ) in the charts are the default settings of the “MX”. The charts are in the Default Settings of the Transmitter and “MX” Receiver section of this guide. To communicate with a host system properly, program the “MX” to match the host system’s requirements. However, the Enter/Exit Program Mode bar code in the MS4120 Programming Guide will not cause your “MX” to enter or exit program mode. Scan the Enter/Exit Program Mode for the Receiver bar code in the following procedure. Once the MS6130 is assigned an ID number, configure the “MX” to the correct communication protocol.

1.Scan the following bar code to enter program mode. (The “MX” receiver will beep three times):

Enter/Exit Program Mode for the Receiver

01 2 3 4 5

 

 

 

 

 

 

 

 

 

 

 

 

 

6 6 6 6 6

 

 

 

7

2.Scan the following bar code to confirm the receiver is using the original factory settings.

Recall Defaults

D F 1

3.Scan the appropriate communication options in the MS4120 and MS951 Programming Guides.

4.Exit program mode by scanning the following bar code. (The “MX” receiver will beep three times):

Enter/Exit Program Mode for the Receiver

01 2 3 4 5

 

 

 

 

 

 

 

 

 

 

 

 

 

6 6 6 6 6

 

 

 

7

10

Image 14
Contents Metrologic INSTRUMENTS, INC Locations Table of Contents Table of Contents MS6130 Hand Held BAR Code Scanner MX003 Series Scanner Interfaces Receiver Group Unpacking ListTransmitter Group Connections of the Mxnterfacei to the Host Device Except versionConnections of the Keyboard Wedge Mxnterfacei to the PC Version 17 onlyConnections of the MS700I/MS720I With Mxto the Host Device Configuration of the MS700I/MS720I with MX Page Configuration of the Mxto the Scanpal Data Collector Page Keyboard Wedge KB Interface KB Parameter Keyboard TypeKB Parameter Keyboard Type KB Parameter Caps Lock Mode Millisecond Delay KB Parameter Alt ModeMicrosecond Delay Millisecond Delay KB Parameter XT Clean-Up BitConfiguration of the MS6130 HAND-HELD Enabling the MS700I/MS720I SCANNER’S RF LOW Speed Option Changing the ID Handset /XMatching Procedure Parts of the MS6130 HAND-HELD BAR Code Scanner Output WindowComponents of the MS6130 Series Stand Installation of the MS6130 Series Stand Installation of the 6000 Series Universal Charging Stand Permanent Counter TOP InstallationNicd Battery Charger with Reconditioning Feature Recommended USEVisual Indicators Razzberry Tone Audible IndicatorsOne Beep Two BeepsAudible Indicators Maintenance LabelsTroubleshooting Specifications Appendix aMX003 Series Scanner Interface Specifications Temperature Characteristics Degrees Celsius of each Cell Default Settings of the MS6130 and MX Receiver Appendix BRTS/CTS UPC EAN Parameter Transmitter Default Keyboard Receiver Wedge Pin Function Appendix CMX003 Series Scanner Interface Pin Assignments Warranty and Disclaimer Appendix DAppendix E Appendix F PatentsIndex ESDTroubleshooting