Manual Thickness Adjustment

This scanner is initially set to automatically detect the thickness of paper during scanning. This function, however, may not function properly when scanning extremely thick or thin paper. If this happens, the user must manually adjust the paper thickness so that documents are fed smoothly through the scanner.

The procedure for manually adjusting the paper thickness is as follows:

1 Press the function key to which Manual Thickness Adjustment is registered (default is function key 1).

The function key blinks, and “Adj” appears blinking on the counter display. The

Semi-Auto lamp at Feeding Option lights, and the Start key blinks green.

Scanner

A

MEMO

To cancel the manual paper thickness adjustment function, press the blinking key or the Stop key.

2 Load one sheet from the document to be scanned on the document tray, and press the Start key.

This scans the document, and the paper thickness is displayed on the brightness indicator.

MEMO

The paper thickness displayed on the indicator does not represent the exact paper thickness, but serves as an aid when adjusting the paper thickness.

3 Press the or key to adjust the paper thickness.

Pressing the or key moves the indicator display to the left and right, respectively.

To set a thicker paper setting, press the key. To set a thinner paper setting, press the key. The paper thickness can be adjusted in 13 steps.

4 Press the blinking function key again.

This sets the paper thickness, and resets the counter display.

MEMO

To enable the value set in the above procedure, you must set Fixed Thickness Mode (See “Fixed Thickness Mode” P. 54).

The paper thickness can also be adjusted by the application. When the paper thickness has been adjusted on both the scanner operation panel and in the application, priority is given to the last made setting.

3

Preparing Documents

Setting Scan Conditions 53

Image 55
Contents Instructions FCC Regulations For 120V models Introduction Scanner This UnitFilmer Contents Chapter Daily Cleaning Chapter TroubleshootingSpecifications Options Consumables Index Daily maintenance Safety PrecautionsSafety Precautions About the Installation Location Carrying About the Power SupplyChapter Features of DR-5060F About DR -5060F Packaging What’s in the Box?Front view Names and Functions of PartsRear view Inside with upper unit openOperation panel Remaining film indicatorFunction keys Clear/Stop key Backup keySpace/Trailer key Count Only keyBrightness key Indicator lampsStart key Feeding Option keyDocument eject support plate Removable trayFunction key labels About the Camera Unit Preparation Before Use System Requirements Connecting the Scsi Cable Connecting to a ComputerPreparation Bef ore Use Setting the Scsi ID Setting the Scsi ID and TerminatorSetting the terminator Connecting the power cord Connecting the Power Cord and Ground CableTake the microfilm out of its case Handling the Camera UnitLoading Film Press the release notch to open the camera unit’s coverClose the left cover taking care not to nip the film Preparation Bef ore Use Affixing the Index Label Push the camera unit down onto the main unit Loading the Camera Unit in the DR-5060FRemoving the Camera Unit Press the release notch to open the cover on the right Removing FilmRemove the film Store the film in its case Affixing the Document Guide Labels Preparing for Paper Feeding and EjectionDocument tray extension Document eject tray extension Open the extension wireDocument eject support plate Paper Feed Adjustment Turn the computer on Turning the Power ON/OFFTurning the Power on To turn this unit ON, press the power switchTurn the computer OFF before you turn the scanner OFF Turning the Power OFFPreparing Documents Backup key blinking Filmer Only mode Checking the Operation ModeBackup key lit Backup mode Backup key out Scanner Only modePreparing Documents Count Only key lit Count Only modeWhen counting ends, press the Count Only key to cancel Count Only modeTypes of Documents About DocumentsDocument Loading Precautions Setting Scan Conditions Selecting the Feeding Option Remote Inserted first into the scanner Is lowered when scanning of all pages in the document endsSemi-Auto Semi-AutoAuto Sensor Manual To end scanning, press the Stop key Insert the document one page at a timeFunction Key Settings Press the or key to adjust the paper thickness Manual Thickness AdjustmentPress the blinking function key again Double Feed Detection Fixed Thickness ModeOdometer Indication Restore Memorized SettingImprinter Film DensityUser Mode Setup Items Setting in the User ModeTrailer setting Endorser stamp mode settingSpace feed setting Leader feed settingWhen the final letter of the user mode setting is How to Set the User modeSelect the user mode address using the or key When the final letter of the user mode setting is a numberTroubleshooting When the Scanner is Not Recognized Eject tray extension if it is open TroubleshootingRemoving Paper Jams Paper Jam in the Paper Eject SectionPage Check the intermediate unit for jammed paper Paper Jam in the Feed SectionRemove the jammed paper from the feed section Press the open/close button, and lift up the feed unitGently close the upper unit Removing the Intermediate Unit Push the intermediate unit down Attaching the Intermediate UnitCondition Paper jam has occurred Paper Feed TroubleCondition Double feed cannot be detected Troubleshooting Cause Driver or application does not run correctly When the Scanned Image is Not NormalCause Scanning glasses and rollers on the scanner are dirty Cause Scan conditions are inappropriateWhen an Error Code is Displayed Cause Scanner paper jam Cause Endorser option connection errorCause Lamp has reached the end of its service life Cause Document was skewedAbout the Remaining Film Warning Page Daily Cleaning Cleaning the Main Unit Daily CleaningDaily Cleaning Cleaning the Scanning Glasses and RollersOpen the feed unit Use a clean, dry cloth to wipe the scanning glasses Lower the lever Press this part Fit into Deeper Two grooves Memo Power Cord Cleaning the Camera UnitImprinter Guide Plate SCSI-II SpecificationsBarcode Decoder Camera unitEndorser ED600 ImprinterIndex Auto Backup keySCSI-ID User mode setting Page PUB.CE-IE-986
Related manuals
Manual 87 pages 44.13 Kb

DR-5060F specifications

The Canon DR-5060F is a high-performance document scanner designed primarily for professional environments that require fast, efficient, and reliable document management. This unit stands out due to its blend of advanced technology, usability, and robust features, making it an ideal choice for businesses that process large volumes of documents.

One of the main features of the DR-5060F is its impressive scanning speed. It can scan up to 60 pages per minute in monochrome and 30 pages per minute in color, allowing users to digitize documents quickly and keep operations moving smoothly. This speed does not compromise quality; the scanner produces high-resolution images at up to 600 dpi, ensuring crisp text and detailed graphics that are essential for professional documentation.

The DR-5060F leverages Canon's patented image processing technology, including OCR (Optical Character Recognition). This feature transforms scanned text into editable and searchable formats, greatly enhancing productivity and ease of access. Additionally, the scanner is equipped with Automatic Document Feeder (ADF) that can handle up to 50 sheets at a time. This allows for continuous scanning, providing significant time savings for users.

One of the key characteristics of the DR-5060F is its versatility in handling various document types. The unit easily processes everything from thin or fragile documents to thicker presentations, making it suitable for various applications, including legal, healthcare, and financial services. Furthermore, it supports duplex scanning, enabling double-sided documents to be captured in a single pass.

Another notable technology is the "Active Image Context" feature, which optimizes image quality by automatically adjusting brightness and contrast for each page. This ensures that every scanned document appears clear and professional while minimizing the need for manual adjustments.

In terms of connectivity, the Canon DR-5060F seamlessly integrates with different document management systems. It is compatible with TWAIN drivers, ensuring broad compatibility with many business applications. Moreover, it supports USB connections for easy setup and operation.

In summary, the Canon DR-5060F is a powerful document scanner that merges cutting-edge technology with user-friendly features. Its high-speed capabilities, enhanced image processing, and versatility make it an invaluable asset for businesses looking to improve their document management workflows. Whether for archives, record-keeping, or digitalization projects, the DR-5060F is poised to deliver exceptional performance and efficiency.