Appendix B |
|
| I/O Interface Board | ||
Table | |||||
|
|
|
|
|
|
| Pin # | Signal | Description |
| |
| 1 | Strobe* | Strobe* – This is an output signal used to strobe data into the printer. I/O pin |
| |
|
|
|
| in ECP/EPP mode. |
|
| 2 | PD0 | Parallel Port Data 0 – These signals <0 to 7> provide the parallel port data |
| |
|
|
|
| signals |
|
| 3 | PD1 | Parallel Port Data 1 – Refer to |
| |
| 4 | PD2 | Parallel Port Data 2 – Refer to |
| |
|
|
|
|
|
|
| 5 | PD3 | Parallel Port Data 3 – Refer to |
| |
|
|
|
|
|
|
6 | PD4 | Parallel Port Data 4 – Refer to |
| ||
| 7 | PD5 | Parallel Port Data 5 – Refer to |
| |
|
|
|
|
|
|
| 8 | PD6 | Parallel Port Data 6 – Refer to |
| |
|
|
|
|
|
|
| 9 | PD7 | Parallel Port Data 7 – Refer to |
| |
| 10 | ACK* | Acknowledge – This is a status output signal from the printer. A Low State |
| |
|
|
|
| indicates it has received the data and is ready to accept new data. |
|
| 11 | BUSY | Busy – This is a Status output signal from the printer. A High State indicates |
| |
|
|
|
| the printer is not ready to accept data. |
|
| 12 | PE | Paper End – This is a status output signal from the printer. A High State |
| |
|
|
|
| indicates it is out of paper. |
|
| 13 | SLCT | Select – This is a status output signal from the printer. A High State indicates |
| |
|
|
|
| it is selected and powered on. |
|
| 14 | ALF* | Auto Feed – This is a request signal into the printer to automatically feed one |
| |
|
|
|
| line after each line is printed. |
|
| 15 | ERR* | Error – This is a status output signal from the printer. A Low State indicates |
| |
|
|
|
| an error condition on the printer. |
|
| 16 | INIT* | Initialize – This signal used to Initialize printer. Output in standard mode, I/O |
| |
|
|
|
| in ECP/EPP mode. |
|
| 17 | SLCTIN* | Select In – This output signal is used to select the printer. I/O pin in |
| |
|
|
|
| ECP/EPP mode. |
|
| 18, 19, 20, | GND | Ground |
| |
| 21, 22, 23, |
|
|
| |
| 24, 35 |
|
|
|
|
Notes: The shaded area denotes power or ground. The signals marked with * = Negative true logic.
CoreModule 800 | QuickStart Guide | 33 |