Error Message | FRU/Action in Sequence |
|
|
DMA Test Failed | DIMM |
| System board |
|
|
Software NMI Failed | DIMM |
| System board |
|
|
DIMM | |
| System board |
|
|
Device Address Conflict | Run the Setup Utility, then press F9 to load the system |
| defaults. |
| RTC battery |
| System board |
|
|
Allocation Error for device | Run the Setup Utility, then press F9 to load the system |
| defaults. |
| RTC battery |
| System board |
|
|
Failing Bits: nnnn | DIMM |
| BIOS ROM |
| System board |
|
|
Fixed Disk n | None |
|
|
Invalid System Configuration Data | BIOS ROM |
| System board |
|
|
I/O device IRQ conflict | Run the Setup Utility, then press F9 to load the system |
| defaults. |
| RTC battery |
| System board |
|
|
Operating system not found | Run the Setup Utility and see if fixed disk and drive A: are |
| properly identified. |
| Diskette drive |
| Hard disk drive |
| System board |
|
|
System Error – No Beep |
|
|
|
Error Message | FRU/Action in Sequence |
|
|
No beep, power indicator turns off and the | Power source (battery pack and power adapter). Refer to the |
LCD screen is blank. | “Power System Check” section on page 65. |
| Ensure every internal cables are properly and securely |
| connected. |
| Reinstall the memory module. |
| System board. |
|
|
No beep, power indicator turns on but the | Power source (battery pack and power adapter). Refer to the |
LCD screen is blank. | “Power System Check” section on page 65. |
| Reconnect the |
| Hard disk drive |
| |
| Inverter board |
| LCD panel |
| System board |
|
|
Chapter 1 | 69 |