Positions | Mode |
|
|
OFF | RS232 |
| |
ON |
|
|
|
OFF | RS422, RS485 |
| |
| WITHOUT polarisation and termination resistors |
ON |
|
|
|
OFF | RS422, RS485 |
| |
| WITH polarisation and termination resistors |
ON |
|
Table 10: Serial mode configuration switches
Note: the 3 switch configurations shown in the table above are the only configurations giving satisfactory results.
Warning: The switch 2 is reserved and must stay OFF. Note that the switches 3 & 4 need to have the same position (both ON or both OFF). When they are ON, this connects the internal polarisation (typ 680 Ohms) and termination (typ 120 Ohms) resistors. This configuration applies only to RS4xx lines conforming to good practices.
5.4.2 Serial port #2
Specification |
| Value |
|
|
|
Physical mode |
| Full RS232 |
|
|
|
Normal isolation |
| NOT ISOLATED |
|
|
|
Pinout connector |
| See label and appendix (Relays output on page 30) |
|
|
|
Termination/polarization |
| None |
|
|
|
| Table 11: Serial port 2 specification |