When cabling over long distance, you have to take care of the twisted pairs. This means that along with the above cabling conventions, the emission (TX+/TX-) and reception (RX+/RX-) signals have to be connected on the same twisted pair:

TX+: pin3, TX-: pin6

Twisted pair 1

 

 

RX+: pin1, RX-: pin2

Twisted pair 2

 

 

Pins 4, 5, 7 and 8 do not have to be connected. The following picture shows the twisted pair connections:

Figure 15: Crossed cable cabling

9.2.2 Connection over hub/router

If the eWON® is connected to a hub, it has to be connected like any other device, with a straight cable. Again, the wiring is as shown on the following picture, and care should be taken to keep the RX and TX signals on twisted pairs:

Hub/Router

Straight

cable

Straight

cable

page 26 of 35

Image 29
Contents Installation Guide EWON4002 Installation Guide Table Of Contents IP parameters configuration Technical support Product description General specification of the hardware platformIntroduction Ethernet GatewayDatalogger RAS Modem & PIRTypical applications Part Numbers and internal optionsCc= Communication External accessoriesXy = Options Type/Description Part NumberStructure of the eWON technical documentation Level Title ContentsHousing Housing and markingsMarkings Required power supplyApplicable directives, standards and compliance Serial numberMechanical outline Equipment information and versionsSpring Bottom Slider Mounting and environmental conditionsSpecifications for external power supply selection Preparing the installationSpecification Value Auto fuseFront panel control LEDs Embedded Pstn Modem Communication interfaces and I/OsEmbedded GSM/GPRS Modem Ethernet PortSIM-card insertion Recommendations for the GSM/GPRS antennaSerial port #1 Serial port Dip switchSerial ports Serial port #2 Positions ModeSerial port #3 Serial port 3 connector and dip switchDigital Inputs Open collector Digital Output Digital OutputsRelays Configurable standard Analog Inputs AI1 AI4Analog Inputs Resistive Temperature Detector Inputs By Ethernet Communicating with the eWONBy phone line or GSM Under Windows 98, NTUnder Windows XP EWONCFG utility and IP parameter window IP parameters configurationUser Reset ResetsFactory Reset Technical supportPower supply Connector Appendix Pinouts and connections Power SupplyEthernet Ethernet ConnectorDirect connection Crossed CableHub/Router Straight Cable Connection over hub/routerRJ 45 connector/cabling RJ45 connectorDigital Input/Output Connector 1 DI / do connectorDigital Input/Output mating female connector included Digital Input/Output connector pinout Pin DescriptionAnalog Input mating female connector included Analog Input ConnectorAnalog Input connector pinout Pin Description Analog InputRelays Output mating female connector included Relay ConnectorRelays output connector pinout Pin Description Relays outputTop face Digital inputBack face Front Face Digital InputSerial ports connectors Female DB9 with 4/40 blocking screws Pinout serial port Pinout serial ports 1 and 3 according to modePin RS232 RS485 RS422 Pin RS232Connector MiniDIN PIN Schneider Signal EWON Signal Name EWON SUBDB9Unitelway/Modbus serial cable DA is connected to B- and DB is connected to A+Pstn phone line mating male connector not included Pstn phone line connectorPstn phone line Connector