Fujitsu SRS-9924 manual Loading or, Modifying Network Data after entering the Spid

Page 75

LOADING OR

MODIFYING NETWORK DATA (after entering the SPID)

NI ONLY

Configuration

Types: EKTS

and CACH

Note: Do not change your SPID unless told to do so by your service provider. In most cases, digital sets will not work without the correct SPID number. If the SPID number is wrong, the set displays the message SPID NG. Enter the correct SPID number, then disconnect and reconnect power to make the set function normally.

This section explains how to use the KEY-ATTR feature in menu mode to load or modify network data. You must load network data with KEY-ATTR if the set is connected to a switch that does not support the terminal downloading function.

If your set is connected to a DMS switch and uses SPM to download data, you may need to modify the data according to instructions from your system administrator.

If the switch has downloaded network data automatically, you can use these procedures to modify the set configuration to conform to your personal preferences. In these procedures, you select a button on your terminal and assign the button a Directory Number, Call Appearance Number, Intercom or Group Intercom Number, or a Feature Number recognized by the network. In a power failure, data on a reconfigured terminal may be lost.

National ISDN (NISDN) supports two configurations on multiple line sets. The configurations are Electronic Key Telephone Systems (EKTS or ACO) and Call Appearance Call Handling (CACH). If SPM has downloaded network data, you need to know which configuration is used so that you can modify the configuration if required. Additionally, you must know which configuration is used if you are entering network data manually.

EKTS and ACO use Directory Numbers for telephone lines and feature numbers for features. You enter these numbers with options 2 and 3 of KEY-ATTR.

5

NI / 5E Custom Terminal Installation

5-7

Image 75
Contents Page Appendix Terminal Testing Terminal Intro & Table of ContentsTerminal Overview Using Terminal Set-Up SRS-9924-ABM Terminal Installation Terminal AccessoriesFujitsu NI / 5E Custom Terminal Intro & Table of Contents Fujitsu NI 5E Custom Terminal Intro Table of Contents Mfgrs Port Facilities Service Order Network Jack HOW to USE this Guide Conventions and Layout DMS-100Ewsd DIR Isdn Concepts Spid Table of Contents Appendix a Testing Appendix B Appendix CAppendix D SRS-9924 National Isdn Front Panel NI / 5E Custom Terminal OverviewSRS-9924 5E Custom Front Panel 5E Custom Terminal OverviewSRS-9912-SP National Isdn Front View SRS-9912-SP 5E Custom National Isdn Front View OverviewRear stand Unique Components Switches Connectors LED Indicators NI utilizes Feature Activators 19 or MIC-OFF Button Function Keys Permanent FunctionsFunction Button Layout For Multifunction Keys Buttons MultifunctionExample Line Assignment SRS-9924 NI / 5E Custom TerminalUNA NI only5E Custom only Softkeys and MenuUsing the Terminal 5E Custom onlyLine Parameters Using Terminal Autohold OnetouchSRS-9924 and SRS-9912-SP are equipped with Using the Terminal Receiving Handsfree Calls Placing Headset Calls Method If you are using the handset and want to use handsfree modeOnly 5E CustomFunction Isdn Redial Dropping Out Conference Call Transfer Transfer DMS-100, NI1 ONE-TOUCH Calling Using Terminal UNA UNA-LIST Personal Directory DIRUsing the NI / 5E Custom Terminal Set-UpStandard Softkey Layout 5E Custom only NI only Using 5E Custom Terminal Set -UpSelecting a Menu Option Options at any time, as followsUsing the NI / 5E Custom Terminal Set-Up Programming a One-Touch ButtonNumbers you program can be any of the following Enter Directory Number Multifunction button again. The Enter Mode main menu, press asteriskAssociated LED turns green, and the word Correct number4 7 6 2 9 , 9 9 , , 2 5 0 Enter Directory Number Setting the Calendar /CLOCK Enter the present date 1 to 31 and then press To leave it as is, press Options again Enabling the UNA FeatureTerminal Set -Up To return to normal operation, press OptionsTo support UNA on all CAs, follow these steps NI / 5E Custom Terminal Set-UpOptions 4 Enter If the following screen appears, the feature is enabledHeadset Mode Handset Mode Handsfree Supported This feature enables and disables the speakerphone functionPress ENTER, and this screen appears Using the Handset or a HeadsetSetting Ringer Tone Selecting Ringer Pattern Selecting Ringer Pattern ModeDelimiter Access CodeAssigning a Leased NetworkAppears on the display Goes off and the indicator of the new buttonAs the delimiter key. Its indicator goes out Turns green. The number of the new buttonRinger Always On Call Announce Intercom on Selected Buttons Specifying the Directory Number for Intercom Select from the followingEnter the following appears TWO WAY Turned on Example 919 926-3112 or Example 919*926*3112 Screen should now appear as followsPress Options to return to standard display NI only Repeat steps 2 and 3 until this screen appearsPreference options determine which CA Press the desired preference number, then Selecting CA PreferenceMIC-OFF 5E Custom only Menu Editing PersonalPress Exit to return to the initial screen Press Enter to display this screenDigits Using NetworkData Directory Full will be displayed.Chapter Using the NI / 5E Custom SRS-9924-ABMAssignments SRS 9924 ABM 5E Custom ABM ButtonSRS-9924-ABM Bottom View 5E Custom SRS-9924-ABM 5ESS Chapter InstallationInstalling the Isdn equipment may be installed in a number Terminal InstallationSETTING-UP Spids This screen is displayed When the is indicating the correct SpidAuto-SPID Manually cleared Auto-SPID displays the following screensDial your voice Spid number and press Enter 5E Custom Terminal Installation Configuration Types Ekts Cach Loading orModifying Network Data after entering the Spid Numbers with options 1 and 2 of KEY-ATTR Key Attribute Configuration DownloadPress 2 to display the options for manual download Manual ConfigurationSelection Call Appearance Cach Call Buttons Secondary or shared Telephone NumberAre always distinctive CA=XXXX Completed If you press an unlit button, the screen looks like thisSet’s indicators show button status as follows You now have two choices If you select an unlit button, the screen looks like thisProvider CA setting. Then you can enter DNsFactory default CA=1 This completes programming of FAs. If youDirectory Number Mode DN=XX Selection Intercom/Group Final screen looks like this This returns you to the menu mode main menuSelection Conference Press selected Conf button. This screen appearsPress ENTER. The selected button’s LED turns green Completed Select Assign KEY Invalid Selection Selection 7 Originating DNPress the selected Multi-assign key OFF = TRM =ORG = Orgip =Selection Designated Call Appearance SRS-9924 Distance between the NT1 and the terminal is up to 230 ft Two Unit Installations Single Unit InstallationsNI / 5E Custom Terminal Accessories AccessoriesHandset Features 5E Custom Terminal AccessoriesOptional ABM mount Wall Kit Terminal is attached to the wall byIllustration. Three screws hold Terminal mount, and two screws holdRemove the screw holding the cartridge ROM CartridgeTerminal To replace the cartridgeWhen the LED test is complete, this screen appears Appendix a TestingNI / 5E Custom Appendix Terminal Testing Entering Test Mode3SOFT3 4SOFT4 PerformingTests 2SOFT2Function KEY Redial Speaker Function KEYFunction KEY Hold ConfMemory Tests Pressing 4 on the numeric keypad starts an Its place if different errors are discoveredTo be handled by your System Administrator Exiting Test ModeNo Route NI / 5E Custom Appendix Error MessagesError Messages Appendix BFacility N/A DiscardedNot Available UnspecifiedImplemented Element ContentsReference Value NON-EXISTENT or notCall is Proceeding ProceedingThreshold Exceeded Unassigned Service DeniedAnnouncement Undefined CodeTable B-4 Uniform Cause Values Cause # Message Displayed NI / 5E Custom Appendix Ordering National Isdn Lines Appendix C Ordering National Isdn LinesSelect that solution package Using IOCsLines and features Configuration listed below. FollowingCNI CFD/CFBCFV MSGIsdn Conference Button/FA = Drop Button/FA Transfer Button/FA =Call Forwarding Variable FA = Appendix 5E Custom Terminal ICI Displays Appendix 5E Custom Terminal ICI Displays NI only To Make a Call To Transfer a Call Custom Commands for NI System only

SRS-9924 specifications

The Fujitsu SRS-9924 is a cutting-edge solution designed for high-performance computing, data storage, and advanced networking applications. This advanced system is centered on versatility, robustness, and efficiency, catering to diverse industry needs including data centers, telecommunications, and enterprise environments.

One of the key features of the SRS-9924 is its scalable architecture. It supports a wide range of configurations, allowing organizations to tailor the system to their specific requirements. This scalability ensures that as data demands grow, the SRS-9924 can adapt seamlessly with additional resources, making it future-proof for growing enterprises.

The SRS-9924 incorporates state-of-the-art processing power, with multi-core processors that enhance computational capabilities while improving energy efficiency. This is complemented by high-speed memory options, which optimize performance for demanding applications. As a result, users experience significantly faster data processing times, which is critical for applications such as real-time analytics and high-frequency trading.

Another notable technology in the SRS-9924 is its advanced networking capabilities. Equipped with robust connectivity options, it supports multiple protocols and architectures, allowing seamless integration into existing IT infrastructures. The system features high-bandwidth options that ensure rapid data transfer and lower latency, which is crucial for applications that rely on speed and reliability.

The Fujitsu SRS-9924 also prioritizes data protection and security. With sophisticated redundancy features and error-checking technologies, the system minimizes data loss risks and enhances reliability. This is particularly important in industries such as finance and healthcare, where data integrity is paramount.

Power management is another area where the SRS-9924 excels. Fujitsu has implemented innovative energy-saving features that not only reduce operational costs but also align with global sustainability goals. This focus on efficiency helps organizations achieve their green IT objectives without compromising on performance.

In summary, the Fujitsu SRS-9924 stands out as a versatile and powerful solution for modern computing challenges. With its scalable architecture, advanced processing and networking capabilities, enhanced security measures, and energy-efficient design, it is well-suited for organizations looking to leverage technology for competitive advantage in today’s data-driven landscape.