Installing the Interface Module

To Install the HP 16500H Hardware

To Install the HP 16500H Hardware

If you need instructions for removing and replacing parts of the HP 16500B, refer to the HP 16500B Logic Analysis System Service Guide.

SHOCK HAZARD Disconnect the power from the mainframe before performing the following procedures. After disconnecting the power, wait at least six minutes for the capacitors on the power supply board and the CRT driver board to discharge before servicing the instrument. Failure to do so could result in electrical shock. Hazardous voltages exist on the power supply, the CRT, and the CRT driver board of the HP 16500B mainframe. As long as the AC LED on the power supply has any illumination, a significant charge remains on the capacitors.

Use grounded wriststraps and mats when performing any service to this module or to the HP 16500B Logic Analysis System. Electrostatic discharge can damage electronic components.

For correct orientation of the cables, match the slots on the cable connectors and on the board connectors.

1Remove power from the HP 16500B mainframe, then remove the measurement modules, the four rear feet, and the top and bottom covers of the mainframe.

2Remove the sheetmetal plate on the rear of the mainframe covering the slot where the interface module will be installed.

With the interface module installed, you will not use the plate. Save the plate to use in case the interface module is removed.

2–2

Image 11
Contents About this Manual HP 16500H Interface Module See Also This BookContents Contents-2 Introducing the HP 16500H Interface Module Introducing the HP 16500L LAN Interface Module Physical Connections Accessories SuppliedRequirements LAN Support Installing the Interface Module To Install the HP 16500H Hardware Installing the Interface Module To Verify the Installation Ethernet LAN Interface Set up the configuration menus on the HP 16500B mainframeMount the HP 16500B system with an NFS mount Verify connectivity with an echo requestHP 16501A Expansion Frame Interface HP 16505A Protoytype Analyzer Verifying the Interface Module Performance Servicing the Interface ModuleVerify the Interface Module Performance Verify the Interface Module Performance Procedure Verify the Interface Module Performance Verify the Interface Module Performance Exit the Test System Troubleshooting an HP 16501A Expansion Frame Troubleshooting in an Ethernet LAN Environment Servicing the Interface Module Removing and Replacing the HP 16500H Interface Module Turn off the power switch located on the front panelRemoving the Interface Module Removing and Replacing the HP 16500H Interface Module Seal the shipping container securely, and mark it Fragile Remove accessories from the moduleReturning Parts Package the module or assembliesOrdering Replaceable Parts Parts listedHP 16500H Interface Module Replacment Parts Replaceable Parts ListPage Cables IndexIndex-2 Document Warranty Product Warranty Declaration of Conformity