Motorola Canopy Backhaul Module Webpage Auto Update the web-based interface. never refresh

Page 44

Default Gateway: enter in an appropriate gateway address for the module. The default value for this parameter is 169.254.0.0.

Color Code: enter in a value (0-254). The color code on the subscriber module and the access point module must match in order for registration to occur. Color code is not a security feature. It is a means for the Canopy System operator to segregate an individual network or neighbor Canopy networks. Also, color code can be used to force a subscriber module to only register to a specific access point module even though the subscriber module may be able to see multiple access point modules. The default value for this parameter is 0 on all Canopy modules.

Display-Only Password: enter the same password in both fields for verification. The display-only password, when used, will allow only view activities to the module. When the display-only password is set and not the full-access password, the display-only password will be tied to telnet and FTP sessions to the module. If the full-access password is also set then it has precedence on the telnet and FTP sessions. If the password is forgotten, the operator will need physical access to the module and will need to create a Canopy “default plug” to override the unit. See steps to create and use a default plug in the section on the Timing Master.

Full-Access Password: enter the same password in both fields for verification. The full-access password, when used, will allow view and change activities to the module. When the full-access password is set, the password will also be tied to telnet and FTP sessions to the module. When prompted for the password via the web-based interface, there is no username required; however when prompted for the password via a telnet or FTP session, the user that MUST be used is “root”. If the password is forgotten, the operator will need physical access to the module and will need to create a Canopy “default plug” to override the unit. See steps to create and use a default plug in the section on the Timing Master.

Webpage Auto Update: the web-based interface. never refresh.

enter time period (in seconds) desired to have the web browser refresh The default setting is 0, which will cause the web-based interface to

SM Power Up Mode with No 802.3 Link: choose which mode the module will default to when there is no Ethernet connection sensed by the module. There are two modes available, the first is Alignment mode and the second is Operational mode. Operational mode is the default setting.

Bridge Timeout Entry: choose the appropriate bridge timeout for correct network operation with existing network infrastructure. It is important that this parameter be set for a longer time period than the ARP (address resolution protocol) cache timeout of the router being used to feed the network.

Authorization Key: each module ships with a unique, pre-programmed authorization key to be used when an operator configures the Canopy System for DES encryption.

Site Name: enter information relating to a name given to the physical module. This parameter will set the supplied information into the sysName SNMP MIB-II object and can be polled by a SNMP management server. The buffer size for this field is 256 characters.

Site Contact: enter contact information relating to the module. This parameter will set the supplied information into the sysContact SNMP MIB-II object and can be polled by a SNMP management server. The buffer size for this field is 256 characters.

Site Location: enter information relating to the physical location of the module. This parameter will set the supplied information into the sysLocation SNMP MIB-II object and can be polled by a

Image 44
Contents User Manua L Important Note on Modifications Exposure Note Hardware Warranty in U.S Trademarks, Product Names, and Service Names Table of Contents Getting Started Accessories Appendix Specifications Getting Started Document Change HistoryModule Description Product DescriptionCanopy Backhaul Operational Mode Alignment Mode Background Information on Networking System Overview and Site Planning DefinitionsSite Selection Criteria Canopy Backhaul Masters SlavePage General Considerations Channel Plans GHz Recommended FrequenciesElectrical Requirements Networking InformationLightning Protection Reflector dishes Security AES Encryption Advanced FeaturesSecurity DES Encryption Password password-if-configured BrandingSpecific information on this MIB see RFC 1213 for details Unpack the Canopy Products InstallationConfiguration of the Backhaul Modules Installation of the equipment Click Enable Aiming Mode AlignmentCabling MAC Address ESN Non-auto-sensing Auto-sensingRJ-45 Crossover Interface Screens Timing Master Timing SlaveTiming Master Quick StartStatus Page Configuration Luid Webpage Auto Update the web-based interface. never refresh Canopy Default Plug Event Log Luid SelectLink Test Time & DateSessions GPS Status Ethernet StatsExpanded Stats Timing Slave Page Configuration Webpage Auto Update the web-based interface. never refresh AP Eval Date Ethernet Stats Link Test Alignment BER Display Accessories Appendix Class Network Portion Host PortionSpecifications HTTP, FTP, SNMP, DESWith passive reflector Lbs kg