120CHAPTER 6: CONFIGURING THE NIC

Configuring the Managed PC Boot Agent (MBA)

This section explains how to configure the Managed PC Boot Agent (MBA) boot ROM to boot from the network.

For detailed information on using, configuring, and troubleshooting the MBA boot ROM, see the Managed PC Boot Agent User Guide, located with the MBA software on the EtherCD.

Enabling or Disabling the Boot ROM Setting

The default NIC boot ROM setting is Disabled. This setting must be enabled to boot from the network.

To enable or disable the NIC boot ROM setting:

1Make sure that the NIC is installed and is connected to the network and that the NIC driver is installed.

2Open the Windows Start menu.

3Select Programs, and then 3Com NIC Utilities.

4Click 3Com NIC Doctor.

The 3Com NIC Diagnostics General screen appears.

5Select the Configuration tab. The Configuration screen appears.

6Under Network Parameter, select NetBoot ROM.

7Open the Set Value list box and select Enabled to enable the boot ROM or Disabled to disable the boot ROM.

8Click OK to save the setting and exit the program.

Booting From the Network

The boot process for the MBA boot ROM varies depending on the type of PC you have (BBS BIOS-compatible or non-BBS BIOS-compatible).

If your PC was purchased recently, it may be BBS (BIOS Boot Specification) BIOS-compatible. The BBS determines how the system BIOS identifies boot devices in a PC (such as a CD-ROM drive, a hard drive, or a floppy drive), allows the user to select the boot order of these devices, and then attempts to boot from each device in the specified order.

Image 120
Contents Part No -1742-001 Published May 3Com Corporation 5400 Bayfront Plaza Santa Clara, California Contents Installing and Connecting the NIC Installing Dynamicaccess Software in Windows Installing Netware Client and Server Drivers Configuring the NIC Troubleshooting the NIC Ethercd Content and Navigation Technical Support About this Guide NIC/Description Model NumberConventions Icon DescriptionConvention Description Overview Product Name/Description Model NumberOnboard 3XP Processor Data EncryptionLAN Encryption Software for Windows 95/98 3CR990 NIC Features High Encryption Pack for Windows3XP Processor Advanced Server Features Load Balancing Self-Healing DriversFailover VLANs Primary failureTraffic Prioritization Server Features Using Other NICs Remote Wake-UpWindows NT and Windows 2000-Planning the Configuration on Remote Wake-Up RequirementsIntegrated Boot ROM with Managed PC Boot Agent MBA Remote Wake-Up and Multiple NIC InstallationsRemote Wake-Up Cable Desktop Management Interface DMI Hot Plug NIC Installation Remote System AlertsDhcp Server Prevention DynamicAccess LAN Agent Offline DiagnosticsWindows 2000 Offload Features Installation Overview Safety PrecautionsInstallation Requirements RAMInstalling From Diskette Installing Multiple NICsUpgrading Windows 95 to Windows Updating the Network Driver and NIC SoftwareMaking a DOS-Bootable Diskette Creating Installation DiskettesProduct Registration Preparing the NIC and the Computer Follow the prompts as they appearDecide whether you want to use Remote Wake-Up Make sure that cable requirements are met Network Envi Cable Required Maximum Ronment Cable LengthInstalling and Connecting the NIC Replace the computer cover and plug in the power cord Carefully insert the NIC in the empty PCI slot, as shownConnecting the Remote Wake-Up Cable Connecting the cable to the NIC backplateReplace the PC cover and plug in the power cord Installing Software Installing NIC Drivers Windows Software Installation RequirementsInstalling the Network Driver Using the EtherCD Getting HelpWindows Windows NT Click NextClick Finish Click Add Click CloseTurn the PC power on Click Yes to restart the PCYou must restart your computer to complete the installation Click Yes to restart your computerNew Hardware Found Update Device Driver Wizard Do one of the followingClick Yes Enter the path to the CD-ROM drive, and then click OK Verifying Successful Installation Right-click the My Computer icon, and then click PropertiesWindows 95 and Windows Select the Resources tabInstalling the 3Com NIC Diagnostics Program Starting the 3Com NIC Diagnostics Program Double-click the 3Com NIC Diagnostics iconUpdating the Network Driver and NIC Software Restart WindowsInstalling Multiple NICs Windows 2000, Windows 98, and WindowsRepeat the process for each additional NIC to be installed Select the Adapters tab Click AddInsert the EtherCD Close the Network screen Installing the DynamicAccess LAN Agent for a Client NIC Client PC RequirementsInstalling the LAN Agent Verifying Successful Installation Configuring the DynamicAccess LAN AgentRestart the PC Installing DynamicAccess Software for a Server NIC Removing the DynamicAccess LAN AgentStart Windows Insert the EtherCD in the CD-ROM drive Installing DynamicAccess Software for a Server NIC Configuring Groups and VLANs for a Server NIC Planning the ConfigurationConfiguring Groups and VLANs for a Server NIC Number of VLANs Working With Server Features WindowsWindows NT Double-click the DynamicAccess SW Server icon To disable all load balancing-ClearCreating a Group Adding NICs to a Group Specifying a Dedicated IP AddressClick the Load Balance/RSL tab Load Balance/RSL window Click Add NICChanging an IP Address Creating a VlanSpecifying Traffic Priorities Saving the ConfigurationClick the appropriate tab Disabling Load Balancing for a Group Changing the Primary NICRemoving a NIC from a Group Click the Load Balance/RSL tabDeleting or Editing a Vlan Displaying NIC PropertiesDisplaying Group Properties Specifying Failover from Gigabit to 10/100 PCITroubleshooting a Load Balancing Configuration Disable load balancing for the groupSymptom Tip Add 3Com server NICs to the groupChanging Windows 2000 Property Settings Identifying Windows 2000 Miniport and LAN ConnectionsUsing Windows 2000 Offload Features Enabling Offloads Value Offload Function Enabled Click ConfigureInstalling DynamicAccess LAN Encryption Software Configuring Offloads for a Group of Different NICsMinimum Installation Requirements Installing LAN Encryption Software on WindowsHardware Requirements Software RequirementsClick NIC Software Click Yes to continue With the Winsock2 Setup screen displayed, click OK Click OK Enter your network password when promptedClick Yes Click OK Insert the Windows 95 CD-ROM and click OK Installing LAN Encryption Software on Windows Click Yes to continue Installing Dynamicaccess Software in Windows Adding the Entrust File Starting DynamicAccess LAN Encryption Software Viewing the Administrator’s Guide OnlineUninstalling LAN Encryption Software Page Installing and Configuring the NetWare Server Driver Using the Latest Support PacksNetWare Version Required Support Pack Latest patch files Obtaining NetWare Loadable Modules NetWare Version Required Support PackNetWare Server NLM Name Server Software Installation Requirements Before installing NICs After installing two NICsNetware Packet Receive Buffers Slot Numbers for Multiple NICsInstalling the NetWare 3.12 Server Driver Obtaining Slot NumbersSave and exit the file, and then reboot the server Press Enter Press Insert againSelect 3C99x, and then press Enter Type the name of the NIC and press EnterPress Enter to save the changes Press Esc to ExitSelect Reinitialize System Loading the 3Com EtherCD Press Enter to select the driverSpecifying the Slot Number Loading the DriverInstalling Multiple Server NICs Load 3C99X.LAN slot=slot1 NAME=name1 FRAME=frametype1Installing Server Features Boot the NetWare server with the -na optionVerifying the PCI Slot Number From the Configuration Options screen select Product optionsEnter this command Configuring GroupsMake the following changes to the AUTOEXEC.NCF file Save the AUTOEXEC.NCF file and return to the server prompt Verifying the Installation and Configuration At the system prompt, enter load monitorSelect a driver to view its associated statistics Changing NetWare Driver Configuration Parameters Log in or map to the serverParameter Range of Values Description Maintaining Groups Install the new secondary NIC Reboot the serverAdding a Secondary NIC to a Group Install the NICs Adding a Group107 Server Feature Commands GroupDisplay status Link timeout HelpProbe interval Receive timeout Send timeoutRetry count Wait timeout UngroupTroubleshooting a Group Configuration Default NIC Settings Option Description SettingsAuto Select ALL Configuration Methods Method Description RequirementsChanging General NIC Configuration Settings Using the 3Com NIC Diagnostics ProgramMethod Description Using the 3Com DOS Configuration Program Click OK to save the changes and exit the programEnter the following at the DOS prompt d\3c99xcfg.exe Configuring the Managed PC Boot Agent MBA Enabling or Disabling the Boot ROM SettingBooting From the Network BBS BIOS-Compatible PCs Make sure that the NIC boot ROM setting is EnabledSet the MBA manually as the first boot device Reboot the PCNon-BBS BIOS-Compatible PCs Change the MBA default boot setting from Local to NetworkDisabling the 3Com Logo Configuring IP Security Encryption Description Type LevelCreating a Security Policy Defining the ConsoleCreating the Policy Select IP Security Policy Management, and then click AddClick Next and then Finish Creating a Filter Select a Specific IP Address in the pull-down listEnter destination IP address, and then click Next Accept the default, and then click Next Binding the FilterCreating the Filter Action Binding the Filter ActionEnabling Encryption Disabling EncryptionInterpreting the LEDs State MeaningViewing the NIC LEDs in the Diagnostics Program LNKAccessing 3Com Support Databases Accessing the 3Com KnowledgebaseAccessing the 3Com NIC Help System Accessing Release Notes and Frequently Asked QuestionsTroubleshooting the NIC Installation Problems/Error MessagesCleaning Up a Failed Installation Troubleshooting the Network Connection Click Proceed Click OKTip Description Troubleshooting Remote Wake-Up Make sure that you are using the latest driver for the NICCheck the computer Bios Check the Remote Wake-Up cable connectionTroubleshooting a Network Connection Connect a straight-through cable from the PC to the hubTroubleshooting Hubs Cabling PinoutsRemoving the Network Driver Exit the Device Manager and shut down WindowsClick the Device Manager tab Removing DynamicAccess Server Features From the Start menu, select Settings/Control PanelEnter this command at the prompt NetWarePage Running NIC Diagnostics Running the 3Com DOS Diagnostics Program Running the NIC Diagnostics TestsReboot the computer using a DOS-bootablediskette Running the Network Test Tab DescriptionViewing the NIC LEDs in the Diagnostics Program Running the NIC TestViewing Network Statistics Click the Statistics tab. The Statistics screen appearsUsing the 3Com Icon in the Windows System Tray Enabling the IconDisplaying Network Statistics Removing the 3Com NIC Diagnostics Program Click Proceed, and then follow the prompts on the screenPage Obtaining Drivers Page Specifications 3CR990 NIC SpecificationsCabling Requirements Twisted-Pair Cable10BASE-T Operation Category UseRJ-45 Connector Pin Assignments 100BASE-TX OperationFlow Control Pause FramesLink Negotiation Page 3C OM DMI a Gent About the 3Com DMI AgentSystem Requirements Installing the 3Com DMI Agent Network Management RequirementsFollow the prompts on the screen Restart the PC when prompted EtherCD Navigation LinksDescriptionRoot Subdirectories Auto InsertText Files Subdirectory Description165 File Name File DescriptionPage Windows Fresh Installation NetWare Fresh InstallationRequirements Installation Instructions Driver Summary screen, select 3C990.LAN and press EnterWhen the installation is finished, edit the STARTUP.NCF file Page Online Technical Services World Wide Web Site3Com Knowledgebase Web Services 3Com Bulletin Board ServiceAccess by Analog Modem 3Com FTP Site3Com Facts Automated Fax Service Access by Digital ModemSupport from Your Network Supplier 847 262Support from 3Com Country Region Telephone Number Asia Pacific RimEurope Returning Products for Repair Country RegionEurope, South Africa, and Middle East Latin AmericaTo obtain an authorization number, call or fax Country Region Telephone Number Fax NumberIndex NumbersMBA PCI NIC 131 NLMs Displaying, Windows Self-healing drivers SHDs OSR2 Index Page FCC Class B Statement Industry Canada Class B Emission Compliance Statement Page Product Registration