ADTRAN QFO-C warranty Changing the Port Service State, Port Service Status Screen

Page 14

NOTE

Port 0 is the QFO-C access module itself.

Changing the Port Service State

From the Service State Screen, type the desired port number and press Enter. The Port Service Status Screen (Figure 9) will appear.

Type the number corresponding to the desired service state. Press Enter.

From the Provisioning screen (Figure 7) type Ò2Ó and press Enter to select All Provisioning. The Provisioning of All Ports Screen (Figure 10) will appear.

Shelf:

Slot:

10

Total Access System

07/15/99 10:42

Unacknowledged Alarms:

MINOR

 

 

 

 

Port 1: Out of Service - Unassigned

 

 

 

1. In Service

 

 

 

 

2. Out of Service - Unassigned

 

 

 

3. Out of Service - Maintenance

 

 

 

Selection:

 

 

 

 

‘?’ - System Help Screen

 

 

 

 

 

 

Figure 9. Port Service Status Screen

 

 

 

 

 

Shelf:

Slot:

10

Total Access System

07/15/99 10:45

Unacknowledged Alarms:

MINOR

 

 

 

Provisioning for All Ports

 

 

 

1.

DSX Equalization

0 to 133' ABAM

 

 

2.

Loopback Timeout

120 Min.

 

 

3.

AIS to DSX (Loss of T1)

Disabled

 

 

4.

AIS to DSX (FLOS)

Disabled

 

 

5.

Restore Factory Defaults

 

Selection:

‘?’ - System Help Screen

Figure 10. Provisioning of All Ports Screen

14

Section 61181300L1-5C, Issue 3

61181300L1-5C

Image 14
Contents Features Revision HistoryCode Input Output WiringCompliance Codes Pin-out For Pair 5 and 7 on TA VOL/SLT GND SLT/VOL Installing the QFO-C Total Access 3000 CO ChassisQFO-C Front Panel Indicators OptionsMenu Structure QFO-C Card ProvisioningFour-Character Display FCD Guidelines Navigating the Menu StructureQFO-C Provisioning Options Line Card QFO-C ProtectionQFO-C FCD Menu Tree Fiber QFO-C Menu Screen QFO-C Main MenuViewing the QFO-C Configuration Screen Entering the Fiber Main Menu ScreenAccessing the QFO-C Provisioning Screen Provisioning ScreenChanging the Port Service State Port Service Status ScreenChanging the Loopback Timeout Value Changing the DSX EqualizationEnabling/Disabling AIS to DSX Loss of T1 Enabling/Disabling AIS to DSX FlosRestore Factory Default Settings Accessing the Status ScreenViewing the Status of a Single Port Viewing the Status of All PortsAccessing the Alarms Screen Viewing AlarmsChanging Alarm Settings and Thresholds Setting the ES Threshold 15-MinSetting the SES Threshold 15-Min Setting the UAS Threshold 15-MinSetting the ES Threshold 24-Hour Setting the SES Threshold 24-HourSetting the UAS Alarm Threshold 24-Hour Setting Up Loopbacks for a TestPerforming Loopback Testing Port Test ScreenAccessing the Performance Monitoring ScreenSwitching the QFO-C from On Line to Protect Viewing Performance Monitoring ScreensSetting the Port Circuit ID Protection Switch Activate ScreenAdtran Repair/CAPS Adtran SalesAdtran Technical Support Repair and Return AddressDS1 L1-5C, Issue