ADTRAN warranty Line Card, QFO-C Protection

Page 9

¥ESCAPE Ð press the switch in the MODE direction and release it between 1.5 seconds and 3 seconds to ascend the menu tree.

¥ROOT - press the switch in the MODE direction and release it after 3 seconds to return to the first element of the Level 1 card menu.

To enter the SCU, MUX, or LINE CARD (T1-OR, HTU-C or QFO-C) menu trees, activate the menu function by performing the following steps:

1.Push the toggle switch momentarily to the MODE position and release.

2.The SCU FCD will enter the login function. Each of the four digits of the password must be individually selected. To select a digit, move the toggle switch momentarily to the SELECT position. To change a digit, move the toggle switch momentarily to the MODE position. The default password is 0000 (four zeros).

3.At the shelf status ÒSTATÓ display, press and release the MODE/SELECT switch in the MODE direction to toggle among menu selections SCU, MUX (if equipped), and

LINE CARD.

4.Press the MODE/SELECT switch in the SELECT direction to select the desired menu item.

4a. For the MUX selection, the FCD displays MUXA. Press and release the MODE/ SELECT switch in the MODE direction to display MUXB (if equipped). Press the MODE/SELECT switch in the SELECT direction to enter the selected multiplexer menu tree.

4b. For the LINE CARD selection, the number of the first occupied line card slot displays (for example, 05). Press and release the MODE/ SELECT switch in the MODE direction until the desired line card slot number displays. Press the MODE/SELECT switch in the SELECT direction to enter the selected line card menu tree.

Figure 4 shows the QFO-C FCD Menu Tree. The MODE command toggles among the selections on the current menu level. For example, if the FCD is

displaying QFO-C ÒSTAT MAJ ALRMÓ (Figure 4, Level 1) and the MODE command is issued, the ÒVIEWÓ menu displays. If the MODE command is issued again, the ÒPROVÓ menu displays, etc.

The SELECT command selects a menu element and descends the menu to the next level. For example, if the FCD is displaying QFO-C ÒALRM PROVÓ (Figure 4, Level 1) and the SELECT command is issued, the ÒESÓ sub-menu displays. If the SELECT command is issued again, the Ò15 MIN ERR THLDÓ sub-menu displays, etc. If a read/write element is selected, the display prompts the user to save the setting. The message ÒSAVEÓ flashes on the display followed by the message ÒNO.Ó If the user wishes to go back to the original setting, press the MODE/ SELECT switch to SELECT. If the user wishes to choose the new setting, press the MODE/SELECT switch to MODE. The message ÒYESÓ displays. Press the MODE/SELECT switch to SELECT to have the new setting take effect. After selecting the new setting, the display returns to flashing between the option name and the current setting for that option. The MODE switch can then be used to scroll through the remaining options.

The ESCAPE command ascends the menu tree. Issuing an ESCAPE command on any menu item ascends the menu one level and displays the first element on that level. For example, if the FCD is displaying QFO-C Ò20 MINÓ on level 3 of Figure 4 and the ESCAPE command is issued, the ÒLB TOUTÓ menu displays. If the element is a read/write value, it maintains its original value.

The ROOT command ascends to the first element of the Level 1 card menu. If the ROOT command is issued from any non-level 1 location, the menu displayed is the first element of level 1. For the QFO-C Menu Tree (Figure 4), the FCD displays QFO-C ÒSTATÓ (first element of Level 1). If the ROOT command is issued from a level 1 location, the software interprets the ROOT command as an ESCAPE command and displays the SCU menus.

QFO-C Protection

Afully-protected system may be established by installing a second (Auxiliary) card to the right of the

61181300L1-5C

Section 61181300L1-5C, Issue 3

9

Image 9
Contents Revision History FeaturesWiring Compliance CodesCode Input Output Pin-out For Pair 5 and 7 on TA VOL/SLT GND SLT/VOL Total Access 3000 CO Chassis Installing the QFO-C Options QFO-C Front Panel IndicatorsFour-Character Display FCD Guidelines QFO-C Card ProvisioningMenu Structure Navigating the Menu StructureQFO-C Provisioning Options QFO-C Protection Line CardQFO-C FCD Menu Tree QFO-C Main Menu Fiber QFO-C Menu ScreenEntering the Fiber Main Menu Screen Viewing the QFO-C Configuration ScreenProvisioning Screen Accessing the QFO-C Provisioning ScreenPort Service Status Screen Changing the Port Service StateChanging the DSX Equalization Changing the Loopback Timeout ValueEnabling/Disabling AIS to DSX Flos Enabling/Disabling AIS to DSX Loss of T1Accessing the Status Screen Restore Factory Default SettingsViewing the Status of All Ports Viewing the Status of a Single PortViewing Alarms Accessing the Alarms ScreenSetting the ES Threshold 15-Min Changing Alarm Settings and ThresholdsSetting the UAS Threshold 15-Min Setting the SES Threshold 15-MinSetting the SES Threshold 24-Hour Setting the ES Threshold 24-HourSetting Up Loopbacks for a Test Setting the UAS Alarm Threshold 24-HourPort Test Screen Performing Loopback TestingScreen Accessing the Performance MonitoringViewing Performance Monitoring Screens Switching the QFO-C from On Line to ProtectProtection Switch Activate Screen Setting the Port Circuit IDAdtran Technical Support Adtran SalesAdtran Repair/CAPS Repair and Return AddressDS1 L1-5C, Issue