Setting the ES Threshold (24-Hour)

From the Alarm Provisioning Screen, type Ò4Ó and press Enter to select ES Threshold (24-Hour). The ES Threshold Screen (Figure 25) will appear. Type the number of the desired setting and press Enter.

Setting the SES Threshold (24-Hour)

From the Alarm Provisioning Screen, type Ò5Ó and press Enter to select SES Threshold (24-Hour). The SES Threshold Screen (Figure 26) will appear. Type the number of the desired setting and press Enter.

Shelf: Slot:

Total Access System

02:24:18 02/18/98

Unacknowledged Alarm: None

 

 

ES Threshold (24 Hour):

14400

1.2880

2.14400

Selection:

? - System Help Screen

Figure 25. ES Threshold (24-Hour)

Shelf: 3 Slot: 11

Total Access System

12/15/99 09:38

Unacknowledged Alarms:

MAJOR

ALERT

INFO

SES Threshold (24 Hour): 7200

1.1440

2.7200

Selection:

‘?’ - System Help Screen

Figure 26. SES Threshold (24-Hour)

22

Section 61181300L1-5C, Issue 3

61181300L1-5C

Image 22
Contents Features Revision HistoryCompliance Codes WiringCode Input Output Pin-out For Pair 5 and 7 on TA VOL/SLT GND SLT/VOL Installing the QFO-C Total Access 3000 CO ChassisQFO-C Front Panel Indicators OptionsMenu Structure QFO-C Card ProvisioningFour-Character Display FCD Guidelines Navigating the Menu StructureQFO-C Provisioning Options Line Card QFO-C ProtectionQFO-C FCD Menu Tree Fiber QFO-C Menu Screen QFO-C Main MenuViewing the QFO-C Configuration Screen Entering the Fiber Main Menu ScreenAccessing the QFO-C Provisioning Screen Provisioning ScreenChanging the Port Service State Port Service Status ScreenChanging the Loopback Timeout Value Changing the DSX EqualizationEnabling/Disabling AIS to DSX Loss of T1 Enabling/Disabling AIS to DSX FlosRestore Factory Default Settings Accessing the Status ScreenViewing the Status of a Single Port Viewing the Status of All PortsAccessing the Alarms Screen Viewing AlarmsChanging Alarm Settings and Thresholds Setting the ES Threshold 15-MinSetting the SES Threshold 15-Min Setting the UAS Threshold 15-MinSetting the ES Threshold 24-Hour Setting the SES Threshold 24-HourSetting the UAS Alarm Threshold 24-Hour Setting Up Loopbacks for a TestPerforming Loopback Testing Port Test ScreenAccessing the Performance Monitoring ScreenSwitching the QFO-C from On Line to Protect Viewing Performance Monitoring ScreensSetting the Port Circuit ID Protection Switch Activate ScreenAdtran Repair/CAPS Adtran SalesAdtran Technical Support Repair and Return AddressDS1 L1-5C, Issue