ADTRAN QFO-C warranty Viewing the Status of a Single Port, Viewing the Status of All Ports

Page 18

Viewing the Status of a Single Port

From the Status Screen, type the number of the desired single port and press Enter. The Port Status Screen (Figure 17) will appear.

Viewing the Status of All Ports

From the Status Screen, type Ò5Ó and press Enter to select All Ports. The Status of All Ports Screen (Figure 18) will appear.

Shelf: Slot:

Total Access System

02/18/98 02:24:18

Unacknowledged Alarms: None

 

 

 

Port 1 Status

Near End

Far End

 

 

 

Port

Disabled

Disabled

 

Loss of Signal

No

No

 

Loop Back DSX

No

N/A

 

Loop Back RT (Network)

N/A

Yes

 

Loop Back RT (Customer)

N/A

No

 

Severely Errored

No

No

 

Errored

No

No

 

Framing (Customer)

No

No

 

ESF Framing (Customer)

No

No

 

Unframed T1 (Customer)

No

No

‘?’ - System Help Screen

Figure 17. Port Status Screen

Shelf:

Slot: 10

Total Access System

07/15/99 10:43

Unacknowledged Alarms: None

 

 

 

 

Status of All Ports

 

 

 

 

 

Near End

Far End

 

Fiber Loss

 

No

No

 

Laser Bias Alarm

No

No

 

Adjacent Card

 

Present

N/A

 

On Line

 

No

No

 

Switched Manually

No

No

 

RT Auto Mode

 

No

No

 

Port 1

 

Disabled

Disabled

 

Port 2

 

Disabled

Disabled

 

Port 3

 

Disabled

Disabled

 

Port 4

 

Disabled

Disabled

‘?’ - System Help Screen

Figure 18. Status of All Ports Screen

18

Section 61181300L1-5C, Issue 3

61181300L1-5C

Image 18
Contents Features Revision HistoryWiring Compliance CodesCode Input Output Pin-out For Pair 5 and 7 on TA VOL/SLT GND SLT/VOL Installing the QFO-C Total Access 3000 CO ChassisQFO-C Front Panel Indicators OptionsMenu Structure QFO-C Card ProvisioningFour-Character Display FCD Guidelines Navigating the Menu StructureQFO-C Provisioning Options Line Card QFO-C ProtectionQFO-C FCD Menu Tree Fiber QFO-C Menu Screen QFO-C Main MenuViewing the QFO-C Configuration Screen Entering the Fiber Main Menu ScreenAccessing the QFO-C Provisioning Screen Provisioning ScreenChanging the Port Service State Port Service Status ScreenChanging the Loopback Timeout Value Changing the DSX EqualizationEnabling/Disabling AIS to DSX Loss of T1 Enabling/Disabling AIS to DSX FlosRestore Factory Default Settings Accessing the Status ScreenViewing the Status of a Single Port Viewing the Status of All PortsAccessing the Alarms Screen Viewing AlarmsChanging Alarm Settings and Thresholds Setting the ES Threshold 15-MinSetting the SES Threshold 15-Min Setting the UAS Threshold 15-MinSetting the ES Threshold 24-Hour Setting the SES Threshold 24-HourSetting the UAS Alarm Threshold 24-Hour Setting Up Loopbacks for a TestPerforming Loopback Testing Port Test ScreenAccessing the Performance Monitoring ScreenSwitching the QFO-C from On Line to Protect Viewing Performance Monitoring ScreensSetting the Port Circuit ID Protection Switch Activate ScreenAdtran Repair/CAPS Adtran SalesAdtran Technical Support Repair and Return AddressDS1 L1-5C, Issue