ADTRAN QFO-C warranty Compliance Codes, Code Input Output, Wiring

Page 2

¥Installs in both the Total Access 3000 (23-inch) and the Total Access (19-inch) chassis.

¥End-to-end transmission for one to four DS1 circuits

¥Operating wavelength 1310 nm

¥Single mode fiber operation

¥Power budget of 25dB (typical)

¥Launch power of -5dBm (typical)

¥Receiver sensitivity of -35dBm (typical)

¥DS1 receiver sensitivity of -9dBm

¥Optical laser transmitter

¥Configured for Central Office (CO) operation

¥SC connectorized optics

¥Performance monitoring

¥Automatic AMI/B8ZS provisioning

¥Can be equalized for 0 to 655 feet of ABAM cable

Performance monitoring and manual loopback on each DS1

¥Front panel LEDs indicate:

PWR - Power is on or off, flashes during craft panel access

DSX - Individual DSX alarm status is OK, errors or Loss of Signal

TST - Card in loopback test mode ALM - Alarm present

ACT - Online indication

2. INSTALLATION

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

After unpacking the unit, inspect it for damage. If damage is noted, file a claim with the carrier, then contact ADTRAN. See Warranty and Customer Service.

Compliance Codes

Table 1 shows the Compliance Codes. This product intended for use in Restricted Access Areas only, and is intented to be installed in a Type ÒBÓ or ÒEÓ enclosure.

Table 1. Compliance Codes

Code

Input

Output

 

 

 

Power Code (PC)

F

C

Telecommunication Code (TC)

Ð

Ð

Installation Code (IC)

A

Ð

 

 

 

Wiring

The QFO-C can only be used in a DSX-1 fed system. If the QFO-C module is to be mixed in the same shelf with other line technologies such as T1 or HDSL, refer to the wiring for that specific card type (See Section 3, Application Guide, in the Total Access 3000 System Manual). The QFO-C will reach the network via Amphenol connectors Pair 5 through Pair 8, located on the backplane, which correspond to DSX-1 connectors A and B. See Table 2. Table 3 includes the pin-outs for pairs 5 and 7, while Table 4 includes the pin-outs for pairs 6 and 8.

Table 2. QFO-only Populated Total Access Chassis

From Total Access

To FDF

To DSX-1

 

 

 

AMP Connector Pair 5

 

DSX-1 IN B

 

 

 

AMP Connector Pair 6

 

DSX-1 OUT B

 

 

 

AMP Connector Pair 7

 

DSX-1 IN A

 

 

 

AMP Connector Pair 8

 

DSX-1 OUT A

 

 

 

*RX

RX (IN)

 

 

 

 

*TX

TX (OUT)

 

 

 

 

*Fiber connections are made to the QFO-C via the connector on its PCB.

2

Section 61181300L1-5C, Issue 3

61181300L1-5C

Image 2
Contents Features Revision HistoryCode Input Output WiringCompliance Codes Pin-out For Pair 5 and 7 on TA VOL/SLT GND SLT/VOL Installing the QFO-C Total Access 3000 CO ChassisQFO-C Front Panel Indicators OptionsMenu Structure QFO-C Card ProvisioningFour-Character Display FCD Guidelines Navigating the Menu StructureQFO-C Provisioning Options Line Card QFO-C ProtectionQFO-C FCD Menu Tree Fiber QFO-C Menu Screen QFO-C Main MenuViewing the QFO-C Configuration Screen Entering the Fiber Main Menu ScreenAccessing the QFO-C Provisioning Screen Provisioning ScreenChanging the Port Service State Port Service Status ScreenChanging the Loopback Timeout Value Changing the DSX EqualizationEnabling/Disabling AIS to DSX Loss of T1 Enabling/Disabling AIS to DSX FlosRestore Factory Default Settings Accessing the Status ScreenViewing the Status of a Single Port Viewing the Status of All PortsAccessing the Alarms Screen Viewing AlarmsChanging Alarm Settings and Thresholds Setting the ES Threshold 15-MinSetting the SES Threshold 15-Min Setting the UAS Threshold 15-MinSetting the ES Threshold 24-Hour Setting the SES Threshold 24-HourSetting the UAS Alarm Threshold 24-Hour Setting Up Loopbacks for a TestPerforming Loopback Testing Port Test ScreenAccessing the Performance Monitoring ScreenSwitching the QFO-C from On Line to Protect Viewing Performance Monitoring ScreensSetting the Port Circuit ID Protection Switch Activate ScreenAdtran Repair/CAPS Adtran SalesAdtran Technical Support Repair and Return AddressDS1 L1-5C, Issue