ADTRAN T200 H2TU-R dimensions Open Loop/No Continuity, Shorted Loop, Door Switch Troubleshooting

Page 17

If the cabinet has been opened during the day allowing the heat to escape before proper troubleshooting tests could be conducted, close the cabinet doors and allow the cabinet internal temperature to restabilize. Recheck during the hottest time of the following day before the outside temperature has a chance to drop.

PRIMARY FAN BOARD

If the primary fan board is believed to be damaged, check the following in the listed order immediately upon opening the rear door:

Power is present at the fan board. (Door LED turns On as soon as the rear door is opened.) If the door LED does not turn On, troubleshoot for lack of power.

Manually disable the rear door switch and check the fan LED status:

-If the primary fan LED is Off, the primary fan should be On.

-If the primary fan LED is On, the primary fan should be Off.

If either condition does not exist the primary fan board is suspect and should be replaced.

SECONDARY FAN BOARD

If the secondary fan board is believed to be damaged, check the following in the listed order immediately upon opening the rear door:

Power is present at the fan board. (Door LED turns On as soon as the front door is opened.) If the door LED does not turn On, troubleshoot for lack of power.

Manually disable the front door switch and check the fan LED status:

-If the secondary fan LED is Off, the secondary fan should be On.

-If the secondary fan LED is On, the secondary fan should be Off.

If either condition does not exist the secondary fan board is suspect and should be replaced.

Open Loop/No Continuity

The primary or secondary Door LEDs will remain Off when the rear or front door is opened if the respective primary or secondary power loop has no continuity (Open) between the cabinet and the FPU.

1.Verify the Central Office FPU is online.

2.Check the LED indication on the FPU.

3.If the FPU is sending power but the cabinet is

not receiving it, check the wiring connections at both the cabinet and the FPU.

Shorted Loop

The primary or secondary Door LEDs will remain Off when the rear or front doors are opened if the respective primary or secondary fan powering loop has a short across the tip/ring cable pair between the cabinet and the Central Office FPU.

1.Verify the Central Office FPU is online.

2.Check the LED indication on the FPU.

3.If the FPU is sending power but the cabinet is not receiving it, check the wiring connections at both the cabinet and the FPU.

Door Switch Troubleshooting

Door switches can fail in either the Closed or Open position. The next two procedures will identify the particular failure. The procedure applies to both front and rear door switches.

WARNING

High Voltages are present on exposed pins. Do not contact exposed surfaces.

Door Switch Failure-Closed

1.Verify with the CO that the FPU is online.

2.Push in and release the door switch.

3.If the Door LED is On, the door switch is not defective.

4.If the Door LED stays Off, regardless of the door switch position, proceed with Step 5.

5.Disconnect the JP2 door switch connector on the fan board by carefully pulling the connector off the header. DO NOT PULL ON WIRES.

6If the Door LED turns On, the corresponding door switch is defective.

7.Follow the door switch replacement instructions to replace the defective door switch.

Door Switch Failure-Open

1.Verify with the CO that the FPU is online.

2.Push in and release the door switch. The Door LED should go On.

3.Manually disable the door switch by centering the rod and pulling outward.

4.The Door LED should go Off.

5.If the Door LED stays On regardless of switch position, proceed with Step 6.

61150090L1-5A

Section 61150090L1-5A, Issue 1

17

Image 17
Contents Revision History GeneralPractice Review DescriptionCabinet Access FeaturesT200/T400 Cabinet Basic Features MountingCabinet Assembly, Rear View Door Power LED Status Indicator LEDsInstallation Pad Mount InstallationLifting Detail Assembly Pole Mount Installation Pad Mounting Bracket InstallationPole Mount Hardware Mounting Bracket AssemblyFrame Mount Bottom Support Bracket AssemblySeal Grommet Kit Cable Stub EntryII. Shielding Shield Connector AssemblyIII. SHRINK-WRAP Splice Module Splice ModuleFnid Circuit Technology Configuration Chart PartCable Pair Tip Ring Door Switch Testing GeneralVerify Power at the Fan Boards Fan Board IndicationFan Operation Fan Board TroubleshootingVerify Proper Connections Abnormal Condition Turning the Secondary Fan OnDoor Switch Failure-Closed Door Switch TroubleshootingDoor Switch Failure-Open Open Loop/No ContinuityReplacement Item Part Numbers MaintenanceSurge Arrester Replacement Desiccant RenewalDoor Gasket Replacement Warranty and Customer Service Customer & Circuit Information