ADTRAN T200 H2TU-R dimensions Pad Mounting Bracket Installation, Pole Mount Installation

Page 6

 

 

sealing washer

 

nut*

 

 

split

 

 

washer*

 

 

flat

bolt torque:

 

washer*

 

 

100-110 in-lbs

Mounting

Pad mounted stud*

 

Bracket

 

(4 places)

 

 

 

 

*Customer supplied

 

Pad arrangement is representative

5/8" dia

Figure 6. Pad Mounting Bracket Installation

9.Hoist the cabinet to an upright position and center it over the pad.

CAUTION

The minimum internal bend radius for cable stubs is nine inches.

10.At this time, on the cable stub model, the cable stubs should be fed through their designated conduit or other route per craft plan.

11.Lower the cabinet with attached brackets onto the pad ensuring the four bottom bracket

5/8 inch bolt holes align with the pad fastener arrangement. Secure with customer supplied fasteners. Continue feeding the cable stubs as the cabinet is lowered.

12.On the ground lug on the cabinet bottom next to the spare cable penetration attach an appropriately sized (6 AWG) ground cable to the most direct path to ground. Ground cable and connectors are customer supplied.

CAUTION

Without positive ground surge protection is lost.

13.After the cabinet is secured to the pad the front and back security access covers can be installed

on the pad mounting brackets using the included fasteners. Tighten to 10-15 in-lbs. Install with the access cover lip facing in and against the cabinet’s bottom panel. See Figure 4.

13.If lifting details are to be removed, replace the fasteners removed in step 4 ensuring the sealing washers are installed next to the cabinet side panels.

Pole Mount Installation

Pole mounting has two configurations:

Mounted to a single pole on either the left or right side panel.

H-frame where the cabinet is supported by a frame arrangement at either the left or right side panel.

The pole-mount or H-frame support structure must bear the weight of a fully equipped cabinet (200 Lbs). The weight and the distance the cabinet will be installed above the ground determines the type of pole configuration to be selected. Refer to Figure 7 for pole mount access clearances.

1.At the installation site remove all packaging material enclosing the cabinet.

2.Remove and set aside the Mounting Hardware Kit. Verify kit contents per Table 3.

3.The cabinet is bolted to two boards running across the wood box frame. Remove the screws securing the two boards to the wood box frame.

63"

with

 

 

 

 

 

 

 

overall

open

 

 

 

doors

 

 

 

 

 

 

33"

 

 

 

to

bottom

 

 

top

 

included

 

 

 

 

 

 

brackets

 

Figure 7. Pole Mount Dimensions

6

Section 61150090L1-5A, Issue 1

61150090L1-5A

Image 6
Contents Practice Review GeneralRevision History DescriptionT200/T400 Cabinet Basic Features FeaturesCabinet Access MountingCabinet Assembly, Rear View Installation Status Indicator LEDsDoor Power LED Pad Mount InstallationLifting Detail Assembly Pad Mounting Bracket Installation Pole Mount InstallationMounting Bracket Assembly Pole Mount HardwareBottom Support Bracket Assembly Frame MountCable Stub Entry Seal Grommet KitShield Connector Assembly II. ShieldingIII. SHRINK-WRAP Splice Module Splice ModuleCircuit Technology Configuration Chart Part FnidCable Pair Tip Ring Verify Power at the Fan Boards Testing GeneralDoor Switch Fan Board IndicationVerify Proper Connections Fan Board TroubleshootingFan Operation Abnormal Condition Turning the Secondary Fan OnDoor Switch Failure-Open Door Switch TroubleshootingDoor Switch Failure-Closed Open Loop/No ContinuitySurge Arrester Replacement MaintenanceReplacement Item Part Numbers Desiccant RenewalDoor Gasket Replacement Warranty and Customer Service Customer & Circuit Information