Door Switch Replacement

The door switch can be replaced in the field if it is damaged or becomes defective.

WARNING

High Voltages are present on exposed pins. Do not contact exposed surfaces.

The following procedure applies to either the front or rear door switch (Figure 16):

1.On the affected switch trace the wires to the fan board JP2 connector. Disconnect by pulling the connector out of the header. DO NOT PULL ON WIRES.

2.Remove the two slide-on terminal connectors on the switch by grasping the heat-shrink insulation and sliding away from the switch. DO NOT PULL ON WIRES.

3.Remove the two Phillips head screws that secure the switch to the cabinet flange and remove the switch.

4.On the replacement switch, identify the COM (common) and NO (normally open) terminals.

5.Position and correctly orient the replacement switch then insert and tighten the two Phillips head screws.

6.Note that one slide-on connector has notched insulation. Slide that connector onto the COM terminal such that the notched side is against the switch.

 

Phillips head screws

COM

 

NO

View from inside cabinet

 

Figure 16. Door Switch

7.Slide the remaining connector onto the NO terminal.

8.At the other end insert the connector into the fan board JP2 header.

9.Conduct a functional test to verify proper door switch operation.

Customer Identification

To easily identify the customer and record circuit information, Table 8 is provided for placement in the plastic holder inside the front door of the cabinet. The Table can be updated when circuits are connected or changed.

5. WARRANTY AND CUSTOMER SERVICE

ADTRAN will replace or repair this product within five years from the date of shipment if it does not meet its published specifications or fails while in service (see: ADTRAN Carrier Network Equipment Warranty, Repair, and Return Policy and Procedure, document: 60000087-10A).

Contact Customer And Product Service (CAPS) prior to returning equipment to ADTRAN.

For service, CAPS requests, or further information, contact one of the following numbers:

ADTRAN Technical Support

(800) 726-8663

Standard hours: Monday-Friday, 7 a.m.-7 p.m. CST

Emergency hours: 7 days/week, 24 hours/day

ADTRAN Sales

(800)827-0807

ADTRAN Repair/CAPS

(256)963-8722

Repair and Return Address

ADTRAN, Inc. CAPS Department

901 Explorer Boulevard Huntsville, Alabama 35806-2807.

2 0

Section 61150090L1-5A, Issue 1

61150090L1-5A

Image 20
Contents General Revision HistoryPractice Review DescriptionFeatures Cabinet AccessT200/T400 Cabinet Basic Features MountingCabinet Assembly, Rear View Status Indicator LEDs Door Power LEDInstallation Pad Mount InstallationLifting Detail Assembly Pad Mounting Bracket Installation Pole Mount InstallationMounting Bracket Assembly Pole Mount HardwareBottom Support Bracket Assembly Frame MountCable Stub Entry Seal Grommet KitShield Connector Assembly II. ShieldingIII. SHRINK-WRAP Splice Module Splice ModuleCircuit Technology Configuration Chart Part FnidCable Pair Tip Ring Testing General Door SwitchVerify Power at the Fan Boards Fan Board IndicationFan Board Troubleshooting Fan OperationVerify Proper Connections Abnormal Condition Turning the Secondary Fan OnDoor Switch Troubleshooting Door Switch Failure-ClosedDoor Switch Failure-Open Open Loop/No ContinuityMaintenance Replacement Item Part NumbersSurge Arrester Replacement Desiccant RenewalDoor Gasket Replacement Warranty and Customer Service Customer & Circuit Information