36APPENDIX A: SAFETY INFORMATION
Important Safety | ■ Installation and removal of the EPS must be carried out by qualified | |||
Information | personnel only. |
|
| |
| ■ Always connect the EPS to an earth (ground) connection when you | |||
| connect it to an AC outlet (power supply). | |||
| ■ To comply with European safety standards, the EPS must always be | |||
| connected to an earthed (grounded) outlet. | |||
| ■ The power cord set must be approved for the country in which it is | |||
| used, as indicated in Table 9. | |||
| Table 9 International Safety Information | |||
|
|
|
|
|
| U.S.A. and | ■ | The cord set must be | |
| Canada | ■ | The flexible cord must meet these minimum specifications: | |
|
| |||
|
|
| — No. 18 AWG | |
|
|
| — Type SV or SJ | |
|
|
| — | |
|
| ■ The cord set must have a rated current capacity of at least | ||
|
|
| 10A. | |
|
| ■ The attachment plug must be an | ||
|
|
| with a NEMA | |
|
|
| (15A, 250V) configuration. | |
| Denmark | ■ | The supply plug must comply with section | |
|
|
| standard | |
| Switzerland | ■ | The supply plug must comply with SEV/ASE 1011. | |
|
|
|
|
|
■The appliance coupler (which is the connector to the unit, not to the wall) must have a configuration for mating with an EN60320/IEC320 appliance inlet.
■The socket outlet must be near to the unit and easily accessible. You can remove power from the unit only by disconnecting the power cord from the outlet.
■This unit operates under SELV (Safety Extra Low Voltage) conditions according to IEC 950. These conditions are maintained only if the equipment to which it is connected also operates under SELV conditions.
■Switzerland only:
– The supply plug must comply with SEV/ASE 1011.