3Com 3C10220 manual Solving NBX, Telephone, To resolve the problem

Page 30

30CHAPTER 3: TROUBLESHOOTING

Solving NBX

If power is not reaching an NBX Business Telephone, use the information

Telephone

in Table 7 to resolve the problem.

 

Problems

 

 

 

 

Table 7 Solving NBX Business Telephone Problems

 

 

 

 

 

Problem

Possible Cause

Suggested Action

 

 

 

 

 

No characters appear in

Faulty connection

Verify all physical connections.

 

the telephone LCD display.

 

 

 

 

The telephone may

Supply power to the

 

 

be faulty.

telephone using the standard

 

 

 

external adapter that comes

 

 

 

with the telephone. If any

 

 

 

characters appear in the LCD

 

 

 

display, the telephone is not

 

 

 

faulty.

 

 

 

Note: You do not need to

 

 

 

connect the telephone to the

 

 

 

Ethernet to perform this check.

 

 

Faulty Ethernet

Take the telephone and the

 

 

cable between the

Ethernet cable to the EPS

 

 

telephone and the

location and connect the

 

 

wall jack

telephone directly to an EPS

 

 

 

output port (one of the top

 

 

 

row of connectors).

 

 

 

If information does not appear

 

 

 

in the LCD display, replace the

 

 

 

Ethernet patch cable, being

 

 

 

sure to use one that is wired

 

 

 

for all eight pins.

 

 

 

Note: If information appears in

 

 

 

the LCD display, the EPS,

 

 

 

telephone, power splitter, and

 

 

 

Ethernet patch cable are fully

 

 

 

functional.

 

 

Faulty EPS port

Plug the telephone into

 

 

 

another EPS output port.

 

 

Faulty power

Replace the power splitter.

 

 

splitter

 

Faulty connection between the wall jack and the EPS

Verify that the Ethernet wall jack is connected to the EPS. If that is not the source of the problem, check the cables and connections between the wall jack and the EPS.

Image 30
Contents 3Com Ethernet Power Source Guide 3Com Corporation 5400 Bayfront Plaza Santa Clara, California Contents Troubleshooting About this Guide ConventionsList conventions that are used throughout this guide Year DocumentationComments Compliance3Com Support About this Guide 3COM Ethernet Power Source Overview Power source is designed for use with a standard OverviewFed through the unused pairs 7/8 and 4/5 2 Receive on pins 3 Front Panel Connections LEDs10/100BASE-TX Data and Power Output Ports LED BehaviorTest LED Rear Panel Console PortGuidelines for Network Configuration Sample topologies are shown in and Figure3COM Ethernet Power Source Overview Cabling Patch Panel Laptop with Wireless PCM Card 3COM Ethernet Power Source Overview Installing Ethernet Power Source END Devices Choosing a Suitable SiteUnit, as shown in Figure Rack-mountingStandard 19-inch equipment racks Repeat and for the other side of the EPSInstalling the Ethernet Power Source and END Devices RJ-45 Input Plug per Port Switch Side List the RJ45 input and output plugs per portRJ-45 Output Plug per Port DTE NIC Side Power Splitter CableData Wiring Closet Patch Panel Premises Ethernet Power SourceAccess Point 3Com WirelessInstalling the Ethernet Power Source and END Devices Troubleshooting ProblemsSolving EPS Solving EPS Problems Solving EPS Problems Solving NBX To resolve the problemSolving NBX Business Telephone Problems TelephoneSolving NBX Telephone Problems Solving Wireless Access Point Problems Wiring, hubs, and switches Troubleshooting Safety Information Information Important SafetyConnect it to an AC outlet power supply Connected to an earthed grounded outlet’information de Sécurité ImportanteFrance et Pérou uniquement Sécurité ImportanteWichtige Sicher HeitsinformationenAppendix a Safety Information Technical Specifications for the Ethernet Power Source PIN AssignmentsPin Number Signal Function Pin Assignments3Com Corporation Limited Warranty Warranties Exclusive