ADC EMU-830 user manual Table of Contents

Page 3

Table of Contents

 

Chapter 1: Overview

1-1

New Features

1-1

Standard Features

1-1

Front Panel

1-2

Major Components

1-3

Multishelf TAO

1-3

SNMP

1-6

SNMP Management Information Base

1-7

Traps

1-8

BOOTP and TFTP Protocols

1-9

Xmodem Protocol

1-9

Alarms

1-10

Autonomous Dial-out Alarm Reporting

1-10

External Shelf Clock Backup Circuit

1-11

Chapter 2: Installation

2-1

EMU Jumper Settings

2-1

EMU Installation

2-2

Multishelf Cable Connections

2-4

Local Terminal Connections

2-5

Remote Terminal and Local Shelf Modem Connections

2-7

Management Station Internal Modem

2-7

Management Station External Modem

2-7

Local Shelf Modem for Multishelf TAO

2-7

Shelf Modem for SLIP Operation

2-9

Chapter 3: Menu Navigation and Multishelf Configuration

3-1

Console Menu Navigation

3-1

Console Menu Options

3-1

Multishelf Configuration

3-3

Logging On

3-3

Network Screen

3-4

Logging in to the Main menu

3-4

Main Menu

3-4

Logging into DSL Circuits

3-7

Enabling or Disabling Alarm Reporting

3-8

Config Menu

3-8

Network Parameters Menu

3-8

SNMP Parameters Menu

3-11

Modem Parameters (Configure and Test Dial-out Alarm Reporting)

3-14

Shelf Alarms Menu

3-16

Remote Alarm Reporting

3-17

Set Date and Time

3-17

LTPE-UM-3159-02

iii

Image 3
Contents WorldDSLTM Exchange Office Management Unit Revision History Table of Contents LTPE-UM-3159-02 Table of ContentsSeptember 25List of Figures List of FiguresSeptember 25 21.Xmodem Transfer MessageLTPE-UM-3159-02 Vii List of TablesList of Tables September 25 Viii LTPE-UM-3159-02 Conventions IntroductionOrganization Intended AudienceReader Alert Meaning EU ComplianceInspecting Your Shipment About This Manual September 25Standard Features NEW FeaturesName Mode Function Front PanelEMU-830 List 4A and 6A Front Panel Components Major Components Multishelf TAOSeptember 25 Overview Local Management of a Single Shelf Using RS-232/Telnet Multishelf TAO Network Screen Snmp Ethernet Network Snmp Management Information BaseTraps WorldDSL TrapsTraps Definition Xmodem Protocol Bootp and Tftp ProtocolsAutonomous DIAL-OUT Alarm Reporting AlarmsExternal Shelf Clock and EMU-830 List 6A Backup Circuit External Shelf Clock Backup CircuitOverview September 25 LTPE-UM-3159-02 Location of the Slip Header Connector P6 on the EMU-830 EMU Jumper SettingsInstallation September 25 EMU InstallationInstalling the EMU-830 into Slot 17 of EMS-830 September 25 InstallationBASE-T Multishelf Cable Connections Multishelf Cable ConnectionsLocal Terminal Connections EMU-830 Console Port Pinouts to DB-9 or DB-25 ConnectorConsole port Local Shelf Modem for Multishelf TAO Remote Terminal and Local Shelf Modem ConnectionsAT&F Modem to EMU Serial Cable Pinouts Shelf Modem for Slip OperationModem to Slip Port Cable Pinouts Press this Key To Perform this Function Console Menu NavigationConsole Menu Options Console Menu Navigation KeysProvisioning September 25 Logon, Network, and Main Menu Screen SelectionsScreens and Selections Displays and Functions Multishelf Configuration September 25 ProvisioningLogging On Network Screen Logging in to the Main menu To log in to the Main menuMain Menu Logging in to an HDSL/G.SHDSL Circuit Shelf AlarmsDSL/G.SHDSL Alarm Reporting HDSL/G.SHDSL Line Unit StatusDSL Circuit Alarms in Order of Severity Priority DSL Line Unit Status Conditions State Indicator DescriptionLogging into DSL Circuits Enabling or Disabling Alarm Reporting To enable or disable alarm reporting for DSL circuitsConfig Menu Configure Network Parameters for Multishelf TAO and Snmp Configure EMU Autoconfiguration through Bootp Network ParametersOption Function Snmp Parameters Menu Snmp Parameters Menu Option Function Provisioning September 25 Configure Snmp Community StringsConfigure Snmp Trap Receivers Configure System IdentificationOption Function Modem Parameters Menu Modem Parameters Configure and Test Dial-out Alarm ReportingLOSW* and LOSW1 Alarm Reporting Screen 10. Shelf Alarms Menu 11. Remote Alarm Reporting Menu Item Set Date and Time Remote Alarm ReportingProvisioning September 25 To set the date and time 12. Set Date/Time Dialog Box Change Password13. Change Password Dialog Box Set Shelf ID Provisioning September 25 To set the shelf ID Terminal Settings16. Restore To Factory Defaults Warning Prompt Set to Factory DefaultsInventory Information Screen Reset EMUField Description Data in Inventory Information ScreenManaging Firmware Through the Upload Menu Upload to a Local or Remote Line UnitScreen -2 on 19. Upload Line Unit Menu Item 21. Xmodem Transfer Message September 25 Provisioning Upload Local EMU 23. Upload EMU Menu Item 25. Tftp Upload EMU Prompt Upload Remote EMU 27. Boot Loader Prompt29. Remote EMU Upload Message Provisioning September 25 LTPE-UM-3159-02 Compatibility Power RequirementsEnvironmental Regulatory ApprovalsAppendix a Specifications September 25 LTPE-UM-3159-02 800.366.3891 Sales AssistanceSystems Integration ADC Technical Assistance CenterAppendix B Product Support September 25 LTPE-UM-3159-02 LTPE-UM-3159-02 GL-1 GlossaryGL-2 LTPE-UM-3159-02 Glossary September 25LTPE-UM-3159-02 GL-3 September 25 GlossaryGlossary September 25 GL-4 LTPE-UM-3159-02 Certification and Warranty For Technical Assistance World Headquarters