AXIS | Page 15 |
Function | Pin number | Description |
|
|
|
Microphone/Line in | 1 | Microphone or line level inputs (mono) |
|
|
|
GND | 2 | Ground |
|
|
|
Line out | 3 | Line level audio out |
|
|
|
GND | 4 | Ground |
|
|
|
Note: Connect the signals according to symbols on the terminal block and the description in the image above; then turn the connector 180° and plug into the unit.
SFP-connector - Supports 1 Gbit/s SFP Module.
I/O terminal connector - Used in applications for e.g. motion detection, event triggering, time lapse recording and alarm notifications. In addition to an auxiliary power and a GND pin, the AXIS
•Transistor output - For connecting external devices such as relays and LEDs. Connected devices can be
activated by AXIS VAPIX API, output buttons on the Live View page or by an Event Type. The output will show as active (shown under Event Configuration > Port Status) if the alarm device is activated.
•Digital input - An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, and glass break detectors. When a signal is received the state changes and the input becomes active (shown under Event Configuration > Port Status.).
Function | Pin | Notes | Specifications |
|
|
|
|
GND | 1 | Ground |
|
|
|
|
|
12 V DC | 2 | Can be used to power auxiliary equipment. | Max load = 125mA |
Power output |
|
|
|
|
|
|
|
Configurable | 3 - 6 | Digital input - Connect to GND to activate, or | 0 to + 30V DC |
(Input or |
| leave floating (or unconnected) to deactivate. |
|
Output) |
|
|
|
| Digital output - Internal connection to ground | Max load = 100mA | |
|
| when activated, floating (unconnected) when | Max voltage = + 30V DC |
|
| deactivated. If used with an external relay, a |
|
|
| diode must be connected in parallel with the |
|
|
| load, for protection against voltage transients. |
|
|
|
|
|
ENGLISH
Note: Connect the signals according to numbers on the terminal block and the description in the image above; then turn the connector 180° and plug into the unit.