Cisco Systems UBR7100E manual Cisco uBR7100 Series Front Panel

Page 25

Chapter 1 Product Overview

Cisco uBR7100 Series Routers Physical Description

Figure 1-3shows the front panel for all models of the Cisco uBR7100 series routers.

Figure 1-3 Cisco uBR7100 Series Front Panel

Cisco

uBR7100

SERIES

37637

All Cisco uBR7100 series routers have one power supply with one AC-input power receptacle. A power cable connects the AC-input power supply to the site AC power source. The router’s main power switch is located next to the AC-input power receptacle. Separate power cords are available, depending on the country of operation.

On the side of each chassis are two chassis ground receptacles—choose the most convenient set for a chassis ground connection for a two-hole grounding lug, and the other set can provide a mounting location for the cable management bracket. On the back of the chassis, there is a receptacle for electrostatic discharge (ESD) equipment.

Four internal fans draw cooling air into the chassis (back to front) and across internal components to maintain an acceptable operating temperature. There are four environmental sensors for monitoring the cooling air as it leaves the chassis. For more information on environmental monitoring, see the “Environmental Monitoring and Reporting Functions” section on page 6-2.

Caution To ensure the proper flow of cooling air across the internal components, a port adapter must be installed in the port adapter slot. If no port adapter is installed, install a blank port adapter (the product number is MAS-7100-PABLANK=). Slot 5 has a blank face plate. For proper airflow, make sure that a blank faceplate is always installed in slot 5. (The product number is SM-BLANK=).

The modular port adapter slides into the chassis slot and connects directly to the router; there are no internal cables to connect.

The port adapter, fixed cable interface, and fixed LAN interface connect to two peripheral component interconnect (PCI) buses on the router’s backplane that provide a path to packet I/O memory and the system processor. For more information, see the “Peripheral Component Interconnect Buses” section on page 1-14.

Cisco uBR7100 series routers can be installed on a tabletop or in an equipment rack. Rubber feet for tabletop installation are included in the accessory kit that shipped with your router.

Arack-mount and cable-management kit is also standard equipment included with all Cisco uBR7100 series routers when they are shipped from the factory. The kit provides the hardware needed to mount the router in a standard 19-inch, four-post or telco-type equipment rack. The rack-mount kit also provides the hardware necessary to manage the interface cables attached to the router.

Note Hardware to install the Cisco uBR7100 series in a 23-inch or 24-inch rack can also be ordered separately (the order number is ACS-7100-RMK=).

Cisco uBR7100 Series and Cisco uBR7100E Series Universal Broadband Router Hardware Installation Guide

 

OL-5916-01

1-5

 

 

 

Image 25
Contents Text Part Number OL-5916-01 Corporate HeadquartersCopyright 2004 Cisco Systems, Inc. All rights reserved Iii N T E N T SPreparing for Installation Maintenance EuroDOCSIS Upstream and Downstream Specifications A-5 Purpose PrefaceAudience ViiRelated Documentation OrganizationChapter Description ViiiConventions Bewaar Deze Instructies Safety WarningAvvertenza Importanti Istruzioni Sulla Sicurezza Warnung Wichtige SicherheitshinweiseAviso Instruções Importantes DE Segurança Xii Spara Dessa AnvisningarXiii GEM Disse AnvisningerXiv Terms and Acronyms Xvi Cisco.com Obtaining DocumentationOrdering Documentation XviiDocumentation Feedback Submitting a Service RequestObtaining Technical Assistance Cisco Technical Support WebsiteObtaining Additional Publications and Information Definitions of Service Request SeverityXix Preface Obtaining Additional Publications and Information Product Description Product Overview Cisco uBR7100 Series Models Cisco uBR7100 Series Router Operational Features Cisco uBR7111 and Cisco uBR7111E Cisco uBR7114 and Cisco uBR7114ECisco uBR7100 Series Routers Physical Description DS0 RF Cisco uBR7100 Series Front Panel Ethernet/Fast Ethernet LAN Interface Fixed Interface UnitsRF Cable Interface Port Adapters Field-Replaceable UnitsWAN Technology Product Description End of Life Memory Size Product Number Spare Product Number Flash DisksSdram Memory Total Sdram Memory Configuration Product NumberRack-Mount and Cable-Management Kit Functional OverviewChassis Slot and Logical Interface Numbering Router# show interfaces Indentifing Interface Information in the SoftwareMAC Addresses Peripheral Component Interconnect Buses Online Insertion and RemovalNetwork Processor Card Memory Type Size Quantity Description Location FrontRouter# show version Other InterfacesDS0 RF System LEDs and Reset ButtonSYS RDY LED Label Color State FunctionOL-5916-01 Tools and Parts Required Preparing for InstallationShipping Container Contents Electrical Equipment Guidelines Safety GuidelinesPreparing for Installation Safety Guidelines Chassis Lifting Guidelines Electrostatic Discharge PreventionRack-Mounting Guidelines Site Requirement GuidelinesCisco uBR7114 Router Footprint and Outer Dimensions Temperature and Humidity Requirements Specification Minimum Maximum Power Connection GuidelinesInterference Considerations Plant Wiring GuidelinesEthernet Connections Distance Limitations and Interface SpecificationsPort Adapter WAN Connections Console Port Connections Console and Auxiliary Port ConsiderationsAuxiliary Port Connections OL-5916-01 Physical Placement Installing Cisco uBR7100 Series Universal Broadband RoutersCisco uBR7100 series router Chassis bottom Mounting the Chassis on a TabletopAttaching the Brackets Rack-Mounting the ChassisBrackets can also be installed with the front panel forward Installing the Chassis in a RackAttaching the System Ground Connection Attaching the Ground WireAttaching the Ground Wire to the Grounding Lug Attaching the Cable-Management Bracket Connecting Upstream and Downstream Ports Connecting to the Network10 Connecting the LAN Port to an Ethernet Hub Connecting the Fast Ethernet PortsConnecting to the Console Port Connecting the Console Port and Auxiliary Port12 Connecting a Modem to the Auxiliary Port Connecting a Modem to the Auxiliary Port13 Connecting the AC Power Cord Connecting the PowerChecking Conditions Prior to System Startup System StartupRestricted Rights Legend Starting the SystemSystem LEDs These LEDs remain off during normal operation of the router Troubleshooting Overview Troubleshooting the InstallationBefore You Call for Technical Assistance Identifying Startup Problems Problem Solving Using a Subsystems ApproachLocating the Serial Number on Your Router Troubleshooting Strategy for Startup Problems Troubleshooting the Processor Subsystem Troubleshooting the Power SubsystemTroubleshooting the Port Adapter and Fixed RF Ports Troubleshooting the Network Processor CardQueued messages Troubleshooting the Cooling SubsystemOnline Insertion and Removal MaintenanceEnvironmental Monitoring Environmental Monitoring and Reporting FunctionsParameter High Warning High Critical Displaying Environmental Status ReportsRouter# show environment last Inserting a Flash Memory Card Flash Memory Card UsageFan Failures Front Back Inserting and Ejecting a Flash Disk Memory Card Formatting a Flash Memory Card Removing a Flash Memory CardMemory Card section on page 6-8. Then proceed to Step Copying a Bootable Image onto a Flash Memory CardInsert the new flash memory card into slot Copying Bootable Images Between Flash Memory CardsUpgrading the Sdram Memory Modules Cover screws Removing the Chassis CoverRemoving the Cover Removing the Sdram DimmBack Front 10 Handling the Dimm Replacing the Sdram Dimm11 Inserting the Dimm Replacing the Chassis Cover12 Replacing the Chassis Cover Powering On the RouterOL-5916-01 Physical Specifications System SpecificationsDescription Specification Upstream Modulation If Output Router ModelDocsis Upstream and Downstream Specifications RF SpecificationsSpecification Docsis Specifications1 Minimum Settings2 Upstream Bandwidth Qpsk Data Throughput QAM Data ThroughputTable A-6 Docsis Cable Downstream RF Specifications Minimum Settings2 Your Headend Settings EuroDOCSIS Upstream and Downstream SpecificationsTable A-8 EuroDOCSIS Cable Downstream RF Specifications Integrated Upconverter Specifications OL-5916-01 North American Channel Plans Manufacturers for Headend Provisioning RequirementsManufacturer1 Website or Phone Number Products/Model Agilent Agilent 89411A Manufacturer Website or Phone Number Products/ModelEuropean Channel Plans Agilent Agilent 8591C Tektronix 2715 Sunrise Telecom AT2000R Coaxial Cables Cable SpecificationsIdentifying an RJ-45 Rollover Cable Console and Auxiliary Port Cables and PinoutsRJ-45-to-DB-9 Console Port Cables and PinoutsAuxiliary Port Cables and Pinouts Fast Ethernet Port Cables and PinoutsIdentifying an RJ-45 Crossover Cable RJ-45 Pin Description Identifying an RJ-45 Straight-Through CableFigure C-5 Duplex SC Cable Connector Fiber-Optic Cables and ConnectorsFigure C-8 Laser Caution Label Laser Classification LabelsOL-5916-01 Frequency Allocation Tables B1, G D1, K Standards ComparisonsNtsc Cable Television Channels and Relative Frequencies Freq MHz Carrier Visual Aural Channel Bandwidth Visual Center Freq MHz Carrier Visual Aural Channel Bandwidth Visual Center Ntsc M Cable Television Frequencies for Japan Table D-5 Japanese Channel Assignments Channel Bandwidth Visual Carrier Aural Carrier Number MHz PAL/SECAM Cable Television Channels and Relative FrequenciesChannel Bandwidth Visual Carrier Aural Carrier Number MHz Channel Bandwidth Visual Carrier Aural Carrier Number MHz Channel Bandwidth Visual Carrier Aural Carrier Number MHz OL-5916-01 Site Log Initials DateIN-1 D EIN-2 CPU reset buttonIN-3 PcmciaIN-4 HFC C-1IN-5 Location Memory options Memory types PCI busIN-6 SnmpIN-7 Tap manufacturersIN-8 Wrist straps, attaching