RF Specifications

Table A-3 Typical RF Upstream Bandwidth and Modulation

Upstream Bandwidth

QPSK Data Throughput

16 QAM Data Throughput

 

 

 

200 kHz

0.3 Mbs

0.6 Mbs

 

 

 

400 kHz

0.6 Mbs

1.2 Mbs

 

 

 

800 kHz

1.2 Mbs

2.3 Mbs

 

 

 

1600 kHz

2.3 Mbs

4.5 Mbs

 

 

 

3200 kHz

4.6 Mbs

9.0 Mbs

 

 

 

Table A-4 Typical RF Downstream Modulation

 

 

 

 

Downstream Bandwidth

64 QAM Data Throughput

256 QAM Data Throughput

 

 

 

6 MHz

27.0 Mbs

38.0 Mbs

 

 

 

8 MHz

38.0 Mbs

56.0 Mbs

 

 

 

DOCSIS Upstream and Downstream Specifications

The recommended settings listed in the following tables are based on a hybrid fiber-coaxial cable (HFC) network in which the digital signal is carried 10 dB below the adjacent analog video channel. If the digital signal on your network is carried 6 dB below the adjacent analog video channel, add 4 dB to the recommended settings in Table A-5and Table A-6.

Table A-5 DOCSIS Cable Upstream RF Specifications

 

Specification

DOCSIS Specifications1

Minimum Settings2

Your Headend Settings

 

 

System/Channel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency range

5 to 42 MHz

5 to 42 MHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transit delay, CMTS to furthest

< 0.800 sec

< 0.800 sec

 

 

 

 

 

 

customer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Carrier to noise ratio

> 25 dB (QPSK3)4

> 21 dB (QPSK)4

 

 

 

 

 

 

 

> 25 dB (16 QAM5)4

> 24 dB (16 QAM)4

 

 

 

 

 

 

Carrier to ingress power ratio

> 25 dB

> 25 dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Carrier to interference ratio

> 25 dB (QPSK)4

> 21 dB (QPSK)4

 

 

 

 

 

 

 

> 25 dB (16 QAM)4

> 24 dB (16 QAM)4

 

 

 

 

 

 

Carrier hum modulation

< –23 dBc6 (7%)

< –23 dBc (7%)

 

 

 

 

 

 

Burst noise

< 10 sec

< 10 sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amplitude ripple

0.5 dB/MHz

0.5 dB/MHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Group delay ripple

200 ns/MHz

200 ns/MHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Micro reflections (single echo)

–10 dBc @ < 0.5 sec

–10 dBc @ < 0.5 sec

 

 

 

 

 

 

 

–20 dBc @ < 1.0 sec

–20 dBc @ < 1.0 sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cisco uBR7100 Series and Cisco uBR7100E Series Universal Broadband Router Hardware Installation Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OL-5916-01

 

 

 

 

A-3

 

 

 

 

 

 

 

Image 97
Contents Text Part Number OL-5916-01 Corporate HeadquartersCopyright 2004 Cisco Systems, Inc. All rights reserved Iii N T E N T SPreparing for Installation Maintenance EuroDOCSIS Upstream and Downstream Specifications A-5 Purpose PrefaceAudience ViiRelated Documentation OrganizationChapter Description ViiiConventions Bewaar Deze Instructies Safety WarningAvvertenza Importanti Istruzioni Sulla Sicurezza Warnung Wichtige SicherheitshinweiseAviso Instruções Importantes DE Segurança Xii Spara Dessa AnvisningarXiii GEM Disse AnvisningerXiv Terms and Acronyms Xvi Cisco.com Obtaining DocumentationOrdering Documentation XviiDocumentation Feedback Submitting a Service RequestObtaining Technical Assistance Cisco Technical Support WebsiteObtaining Additional Publications and Information Definitions of Service Request SeverityXix Preface Obtaining Additional Publications and Information Product Description Product OverviewCisco uBR7100 Series Models Cisco uBR7100 Series Router Operational FeaturesCisco uBR7111 and Cisco uBR7111E Cisco uBR7114 and Cisco uBR7114ECisco uBR7100 Series Routers Physical Description DS0 RF Cisco uBR7100 Series Front Panel Ethernet/Fast Ethernet LAN Interface Fixed Interface UnitsRF Cable Interface Port Adapters Field-Replaceable UnitsWAN Technology Product Description End of Life Memory Size Product Number Spare Product Number Flash DisksSdram Memory Total Sdram Memory Configuration Product NumberRack-Mount and Cable-Management Kit Functional OverviewChassis Slot and Logical Interface Numbering Router# show interfaces Indentifing Interface Information in the SoftwareMAC Addresses Peripheral Component Interconnect Buses Online Insertion and RemovalNetwork Processor Card Memory Type Size Quantity Description Location FrontRouter# show version Other InterfacesDS0 RF System LEDs and Reset ButtonSYS RDY LED Label Color State FunctionOL-5916-01 Tools and Parts Required Preparing for InstallationShipping Container Contents Electrical Equipment Guidelines Safety GuidelinesPreparing for Installation Safety Guidelines Chassis Lifting Guidelines Electrostatic Discharge PreventionRack-Mounting Guidelines Site Requirement GuidelinesCisco uBR7114 Router Footprint and Outer Dimensions Temperature and Humidity Requirements Specification Minimum Maximum Power Connection GuidelinesInterference Considerations Plant Wiring GuidelinesEthernet Connections Distance Limitations and Interface SpecificationsPort Adapter WAN Connections Console Port Connections Console and Auxiliary Port ConsiderationsAuxiliary Port Connections OL-5916-01 Physical Placement Installing Cisco uBR7100 Series Universal Broadband RoutersCisco uBR7100 series router Chassis bottom Mounting the Chassis on a TabletopAttaching the Brackets Rack-Mounting the ChassisBrackets can also be installed with the front panel forward Installing the Chassis in a RackAttaching the System Ground Connection Attaching the Ground WireAttaching the Ground Wire to the Grounding Lug Attaching the Cable-Management Bracket Connecting Upstream and Downstream Ports Connecting to the Network10 Connecting the LAN Port to an Ethernet Hub Connecting the Fast Ethernet PortsConnecting to the Console Port Connecting the Console Port and Auxiliary Port12 Connecting a Modem to the Auxiliary Port Connecting a Modem to the Auxiliary Port13 Connecting the AC Power Cord Connecting the PowerChecking Conditions Prior to System Startup System StartupRestricted Rights Legend Starting the SystemSystem LEDs These LEDs remain off during normal operation of the router Troubleshooting Overview Troubleshooting the InstallationBefore You Call for Technical Assistance Identifying Startup Problems Problem Solving Using a Subsystems ApproachLocating the Serial Number on Your Router Troubleshooting Strategy for Startup Problems Troubleshooting the Processor Subsystem Troubleshooting the Power SubsystemTroubleshooting the Port Adapter and Fixed RF Ports Troubleshooting the Network Processor CardQueued messages Troubleshooting the Cooling SubsystemOnline Insertion and Removal MaintenanceEnvironmental Monitoring Environmental Monitoring and Reporting FunctionsParameter High Warning High Critical Displaying Environmental Status ReportsRouter# show environment last Inserting a Flash Memory Card Flash Memory Card UsageFan Failures Front Back Inserting and Ejecting a Flash Disk Memory Card Formatting a Flash Memory Card Removing a Flash Memory CardMemory Card section on page 6-8. Then proceed to Step Copying a Bootable Image onto a Flash Memory CardInsert the new flash memory card into slot Copying Bootable Images Between Flash Memory CardsUpgrading the Sdram Memory Modules Cover screws Removing the Chassis CoverRemoving the Cover Removing the Sdram DimmBack Front 10 Handling the Dimm Replacing the Sdram Dimm11 Inserting the Dimm Replacing the Chassis Cover12 Replacing the Chassis Cover Powering On the RouterOL-5916-01 Physical Specifications System SpecificationsDescription Specification Upstream Modulation If Output Router ModelDocsis Upstream and Downstream Specifications RF SpecificationsSpecification Docsis Specifications1 Minimum Settings2 Upstream Bandwidth Qpsk Data Throughput QAM Data ThroughputTable A-6 Docsis Cable Downstream RF Specifications Minimum Settings2 Your Headend Settings EuroDOCSIS Upstream and Downstream SpecificationsTable A-8 EuroDOCSIS Cable Downstream RF Specifications Integrated Upconverter Specifications OL-5916-01 North American Channel Plans Manufacturers for Headend Provisioning RequirementsManufacturer1 Website or Phone Number Products/Model Agilent Agilent 89411A Manufacturer Website or Phone Number Products/ModelEuropean Channel Plans Agilent Agilent 8591C Tektronix 2715 Sunrise Telecom AT2000R Coaxial Cables Cable SpecificationsIdentifying an RJ-45 Rollover Cable Console and Auxiliary Port Cables and PinoutsRJ-45-to-DB-9 Console Port Cables and PinoutsAuxiliary Port Cables and Pinouts Fast Ethernet Port Cables and PinoutsIdentifying an RJ-45 Crossover Cable RJ-45 Pin Description Identifying an RJ-45 Straight-Through CableFigure C-5 Duplex SC Cable Connector Fiber-Optic Cables and ConnectorsFigure C-8 Laser Caution Label Laser Classification LabelsOL-5916-01 Frequency Allocation Tables B1, G D1, K Standards ComparisonsNtsc Cable Television Channels and Relative Frequencies Freq MHz Carrier Visual Aural Channel Bandwidth Visual Center Freq MHz Carrier Visual Aural Channel Bandwidth Visual Center Ntsc M Cable Television Frequencies for Japan Table D-5 Japanese Channel Assignments Channel Bandwidth Visual Carrier Aural Carrier Number MHz PAL/SECAM Cable Television Channels and Relative FrequenciesChannel Bandwidth Visual Carrier Aural Carrier Number MHz Channel Bandwidth Visual Carrier Aural Carrier Number MHz Channel Bandwidth Visual Carrier Aural Carrier Number MHz OL-5916-01 Site Log Initials DateIN-1 D EIN-2 CPU reset buttonIN-3 PcmciaIN-4 HFC C-1IN-5 Location Memory options Memory types PCI busIN-6 SnmpIN-7 Tap manufacturersIN-8 Wrist straps, attaching