ALIGNMENT & ADJUSTMENTS
6.1.3 Self Diagnostic Mode
If Error code occurs due to malfunction of the printer, perform Self Diagnostic Mode to solve the problem.
The printer works only in the
To enter the
Release the button within 2 or 3 seconds if 78 shows in the DCU. If 00 shows in the DCU, press the button [Up] or [Shift] to select the self+test , and press the button of [Enter] to operate. To stop, press the button of [shift] and [Enter] together.
Code | Description |
|
|
00 | Main Motor Operating System |
| Only the main motor is in operation. |
|
|
01 | Main High Voltage |
| |
| Caution : High voltage probe should be used. |
|
|
02 | Transfer High |
| |
| Caution : High voltage probe should be used. |
|
|
03 | Transfer High Voltage (+)Reference on (THV +) |
| +800 voltage output by MHV terminal. |
| Caution : High voltage probe should be used. |
|
|
04 | DEV/supply High Voltage : DEV/Supply High Voltage Test. |
| The left one of the three LEDs in the |
| high voltage output by each HV |
| age. The middle and right one of the three LEDs are on and |
| HV terminal. |
| Caution : High voltage probe should be used. |
|
|
05 | LSU Operating System |
| The scanning motor of LSU is in operation, the right LED of the three buttons on. Press |
| the [Up] button to Check LD. LD is functioning and the middle button is on. If the LD is |
| normal, all LEDs are on. |
|
|
06 | Pickup clutch on |
| The Solenoid in the printer is in operation. To stop the operation, Press the button [shift] |
| and [Enter] together. |
|
|
Service Manual